HYDRAULIC GENERATORS
INSTALLATION
CLOSED CENTRE HYDRAULIC SYSTEM WITH LOAD SENSING VARIABLE
DISPLACEMENT PUMP
Picture 16: Closed centre hydraulic system with Load Sensing variable
displacement pump
In a closed centre hydraulic system the oil flow is stopped from the pump when
control valve is centered. The pump can rest when the oil is not required to operate
a function. In Load Sensing variable-displacement pump, the flow rate and output
pressure adjusts automatically based on the load of the hydraulic system.