36
HYDRAULIC GENERATORS
INSTALLATION
Ensure that the hydraulic flow of the base machine is sufficient to run the unit.
At least the minimal flow must be available. READ CHAPTER „10. TECHNICAL
SPECIFICATIONS“ for more information.
Picture 24: P-line operational hydraulic flow
In case of hydraulic flow being too high. The flow must be reduced either by
dropping down the rotation speed of base machine’s hydraulic pump or using
flow limiter valve. DYNASET PV-SAE priority valve is recommended.
Picture 25: Base machine’s pumps
Return line must be connected to a hydraulic oil tank in the shortest possible
line in order to keep the return hydraulic pressure under 5 bar in the tank line.
Generally DYNASETs return line is to be connected directly to the return line of a
hydraulic system.
Picture 26: Return line (T) pressure must be under 5 bars.