4-11
6HWXS/RFNRXW0RGH&RPPDQG^)68/0`5HPRWH
The Setup Lockout Mode command allows the host to lock the user out of the Setup Screen.
This command is useful when the other methods of preventing the user from changing Setup
Screen parameters (locking the entire keyboard or making the SET UP switch inaccessible) are
inappropriate. This feature gives the host complete control of the TCS.
The host controls the Setup Lockout Mode using the Set Mode and Reset Mode commands.
When the Setup Lockout Mode is reset (the default), the user can enter the Setup Screen by
pressing the SET UP switch on the optional keyboard, allowing the user to change the Setup
Screen parameters. When the Setup Lockout Mode is set, the SET UP switch on the keyboard
has no effect on TCS operation.
The state of the Setup Lockout Mode is not preserved during loss of power. If a secure system is
required, the host must immediately set the Setup Lockout Mode on reapplication of power. This
can be done by programming the host to respond to a power-up interrupt from the TCS. (For
more information about power-up interrupts, see Power-Up Interrupt Command, in this chapter.)
'()$8/7
Reset. (This setting allows user access to the Setup Screen.)
23(5$72586$*(
None. (This is a remote command only.)
+26786$*(
<ESC>[>5h
Sets the Setup Lockout Mode.
<ESC>[>5l
Resets the Setup Lockout Mode. (The terminator for the reset command is the letter "l",
ASCII 6C hex.)