SYSTEM MANUAL Version 6.03i
15
AUTO
: Sets the output to
600mA or maximum
attainable current up to
600mA.
Pressing and holding key
enters MANUAL mode
where the current can be
manually set to a chosen
output using
▼
&
▲
buttons.
ON/OFF
: Pressing and
holding this key
switches the generator
ON or OFF A quick
press whilst active will
disconnect the output.
STORE
: Stores the present
valued to memory
▼
: Decreases current in
MANUAL mode.
RECALL
: Recalls previously
stored value
▲
: Increase current
in MANUAL
mode.
3. OVERVIEW
This section gives an overview of the Signal Generator and Detector Unit, looking at the
keypad interfaces, displays and icons and connections for each part of the C-SCAN 2010
system.
3.1. Signal Generator – Keypad
3.2. Signal Generator – Display
The Signal Generator has a backlit display, providing the surveyor with the current status
of the Signal Generator while carrying out a survey. The details of the main screen are
listed below.
1.
Battery Capacity
2.
Estimated survey time remaining
for set current
3.
Internal temperature
4.
Battery state indicator -
³
shown
if external power used
5.
Power taken by the Generator
6.
Peak output voltage
7.
Loop Resistance between Signal
Generator, Earth and Pipeline.
This includes the contact
resistance of the earthing system
(Earth Spike, ground bed, etc.) –
usually the main contributor
X
Y
Z
[
\
]
^
99% 06:49 i25°
GENERATOR OUTPUT
SET to 600mA
16w 10.7v 10
Ω