Troubleshooting
Service Instructions 2112-5 - 00.0 - 02/2020
89
Error 29
No pulses from sewing
motor
No pulses from sewing motor
after sewing process starts
(sewing motor does not run)
Check sewing motor and
synchronization; check
connection between I/O
module 9020013 and sewing
motor; read both upper LEDs
at 9020013; left LED
illuminates briefly when
needle up; right LED shows
synchronization pulses
(512 pulses/rotation); if no
LED illuminates when
handwheel is actuated,
check sewing motor power
supply and replace sewing
motor, if required.
If LEDs are OK and motor
does not run before error
message, check connection
between 9020020 and
sewing motor, replace
9020020 or sewing motor,
if required; if motor makes
some stitches before error
message, check connection
between control unit and I/O
module; replace components
as required
Error 30
Sewing motor too fast
During thread cutting, sewing
motor did not reach cutting
speed within error period
Replace sewing motor or
synchronizer
Error 32
Thread cutting position
does not come
During thread cutting, sewing
motor did not reach the
cutting position
Input slower cutting speed
and earlier cutting position;
replace sewing motor or
synchronizer
Error 33
Sewing motor does not
stop
After thread cutting, sewing
motor does not stop within
error period
Input slower cutting speed
and earlier cutting position;
replace sewing motor or
synchronizer
Error 35
Thread breaking
Thread monitor detects
thread breaking
Error 37
Bobbin thread only rest
The photocell at the bobbin
capsule is illuminated; bobbin
empty
If bobbin is not empty, the
photocell is set too sensitive
and needs to be adjusted
Error 41
No part
Photocell FZ21 remains
illuminated during insertion
Adjust photocell sensitivity;
input test 21
Error 42
Photocell not lighted
Photocell FZ21 does not
detect seam end
Seam distance too long;
adjust photocell sensitivity;
input test 21
Code
Meaning
Remedial action
Содержание beisler 2112-5
Страница 1: ...Service Instructions...
Страница 8: ...About these instructions 6 Service Instructions 2112 5 00 0 02 2020...
Страница 40: ...Setting up the machine 38 Service Instructions 2112 5 00 0 02 2020...
Страница 76: ...Programming 74 Service Instructions 2112 5 00 0 02 2020...
Страница 84: ...Maintenance 82 Service Instructions 2112 5 00 0 02 2020...
Страница 86: ...Decommissioning 84 Service Instructions 2112 5 00 0 02 2020...
Страница 88: ...Disposal 86 Service Instructions 2112 5 00 0 02 2020...
Страница 96: ...Technical data 94 Service Instructions 2112 5 00 0 02 2020...
Страница 103: ......