73
C:
FAULT FINDING CHART
CHART NO.1
SYMPTOM - Refrigerator is too WARM and compressor is NOT running.
Check out the following possible faults by first looking at the fault at the top of the
chart. If this is found not to be the fault then move to the next fault in the direction of
the arrows.
Possible fault
Fault finding &
Repair Task No.
Page no
Switched OFF
Switched ON
User maintenance task
D.1.
65
Thermostat
D.2.
67
Fuse in compressor controller
D.3.
69
Fuse in charge Regulator
D.4.
71
Low state of charge of battery
D.5.
72
Wiring
D.6.
75
Solar Photovoltaic Array
D.7.
75
Compressor controller
D.8.
76
Charge Regulator
D.9.
77
Compressor
D.12.
79
Содержание VC150
Страница 1: ......
Страница 3: ...3 SECTION I ...
Страница 4: ...4 ...
Страница 24: ...24 MODULE AND BATTERY WIRING DIAGRAMS SYSTEM WIRING DIAGRAM ...
Страница 25: ...25 SYSTEM WIRING DIAGRAM GENERAL LAYOUT DIAGRAM ...
Страница 26: ...26 GENERAL LAYOUT DIAGRAM ELECTRICAL CIRCUIT DIAGRAM ...
Страница 27: ...27 ELECTRICAL CIRCUIT DIAGRAM REFRIGERATION CIRCUIT DIAGRAM ...
Страница 28: ...28 REFRIGERATION CIRCUIT DIAGRAM ...
Страница 29: ...29 SECTION II ...
Страница 38: ...38 ...
Страница 39: ...39 ...
Страница 42: ...42 ...
Страница 44: ...44 ...
Страница 50: ...50 ...
Страница 124: ...124 ANNEX 1 COMPONENT LAYOUTS OF SOME COMMONLY USED SOLAR REFRIGERATOR ...
Страница 125: ...125 ...
Страница 126: ...126 ...
Страница 127: ...127 ...
Страница 128: ...128 ...
Страница 129: ...129 ...
Страница 130: ...130 ANNEX II ADDITIONAL EPI TOOL KIT NEEDED FOR PHOTOVOLTAIC REFRIGERATOR REPAIR ...
Страница 136: ...136 ...
Страница 137: ...137 ...