74
CHART NO. 2
SYMPTOM-Refrigerator is TOO WARM (above 8
0
C) and the compressor is running
at times.
Check out the following possible faults by first looking at the fault at the top of the
chart. If this is found not to be the fault then move to the next fault in the direction of
the arrows.
Possible fault
Fault finding &
Repair Task No.
Page no
User Maintenance Task
D.1.
Thermostat
D.2.
Low State of Charge of Battery
D.5.
Wiring
D.6.
Solar Photovoltaic Array
D.7.
Condenser Fan (when fitted)
D.10
Charge Regulator
D. 9.
Cooling Circuit
D.11
Compressor
D.12.
System Sizing