Installation and Operation of X-STREAM WASH
Setup Mode Parameter Table
Parameter Mne-
monic
Parameter
Name
Description
Table 1
Default Value
(Fahrenheit)
Table 2
Default Value
(Celsius)
Units
Setpoint
Temperature Set
Point
115°F
46°C
Degrees
Timer 1
Change Water
Cycle Time
4.00
4.00
H:MM
Timer 2
Soap Dispensing
Delay Time
0.45
2.00
M:SS
Timer 3
Soap Dispensing
Time
1.30
0.30
M:SS
Alarm 1
Alarm 1 Set
Point
250°F
107°C
Degrees
Hysteresis
Alarm 1 Hyster-
esis
0.1
0.1
%
Alarm 2
Alarm 2 Set
Point
160°F
72°C
Degrees
Hysteresis
Alarm 2 Hyster-
esis
0.1
0.1
%
Hysteresis
On/Off Hyster-
esis
0.1
0.1
%
Range
Low Set Point
Low Limit
100°F
38°C
Degrees
Range High
Set Point High
Limit
125°F
52°C
Degrees
Содержание X-STREAM WASH
Страница 27: ...27 Installation and Operation of X STREAM WASH K1000 208 240V 1 PHASE UNITS TO 12 2013...
Страница 28: ...Installation and Operation of X STREAM WASH 28 K1000 208 240V 3 PHASE UNITS AFTER 12 2013...
Страница 29: ...29 Installation and Operation of X STREAM WASH K1000 208 240V 3 PHASE UNITS TO 12 2013...
Страница 30: ...Installation and Operation of X STREAM WASH 30 K1000 440 480V 3 PHASE UNITS AFTER 12 2013...
Страница 31: ...31 Installation and Operation of X STREAM WASH K1000 440 480V 3 PHASE UNITS TO 12 2013...
Страница 34: ...Installation and Operation of X STREAM WASH 34 K5000 208 240V 3 PHASE W SANITIZER...
Страница 35: ...35 Installation and Operation of X STREAM WASH K5000 420 480V 3 PHASE W SANITIZER...