background image

33

Installation and Operation of X-STREAM WASH

K5000 440-480V, 3 PHASE

U

SB

T-cp

l 1

P10

T-

cpl 2

P12

T-

cpl 3

P11

T-cp

l 4

P13

12Vur

GND

RX

TX

P1

P2

12V

0-10

V

VF

D En

ab

le

B

eepe

r

12V

VF

D_ft1

San 

Float

GND

G

ND

IO4

pcb

P14

P15

P17

P4

P16

P3

VFD_ft2

VFD_ft3

Hi L
imit 1

Ch

em P2

Hi L
imit 2

Ch

em P1

SW1

SW2

TRIAC PCB

Che

m

 P2

Che

m

 P1

HL 

2

HL 

1

12001

PW
R P
CB
 

12V

208 / 230V

P5

Wa

sh T

-co

uple

 Water

Wash

 T-c

oup

le –

D

ry

 Fir

e

Beeper 

External 

USB

S1

SC

A1

AC

S/L

2

T/

L3

R/L1

U/T1

V/T

2

W/T

3

Var

iab

le 

Fq

. D

riv

e

T-

cou
ple

Dry Fire

W

ash Wate

r Temp

CHEM. 

PUMP 1

WASH 

PUMP 1

WASH 

PUMP 2

WD DMC K5000

480V

Duke Mfg NPD-StL 3/2/17 ts 

Front Cover

P1 P2 PC

MA

MC

HC

H1

L1

L2

L3

N

Wash Element: 

(2.5K, 5K, 7.5KW)

High 

Limit

COIL

CONTACTOR

Cooling 

Fan

BRN

BRN

RED

BLU

B

LK

BL

K

RE

D

RE

D

RE

D

B

RN

RED
BRN

BRN

BLU

BLU

B

RN

BLU
BRN

YE

L

O

RN

BLK

RED

BLK

RED

BR

N

BL

K

BL

K

RED

RE

D

B

RN

WH

T

O

RN

YE

L

BL

K

BR

N

G

RN

RED

G

RY

B

LU

GR

N

Y

EL WHT

YEL

RED

BLK

BLU

GRN

RED

BLU

BRN

GR
N

B

LK

OR
N

BRN

BLK

BLK

RED

BLK

RED

COIL

Contactor

Control Panel 

Power Switch

1   2   3 

  4

Sw 1

1   2   3

   4

Sw 2

BR

N

BLU

Transformer

Содержание X-STREAM WASH

Страница 1: ...is Copyright 2017 Duke Manufacturing Co All rights reserved Reproduction without written permission is prohibited Duke is a registered trademark of the Duke Manufacturing Co Duke Manufacturing Co 2305...

Страница 2: ...MENT 6 D PLUMBING REQUIREMENTS 6 E ELECTRICAL CONNECTIONS 7 F XSTREAM WASH OPTIONS 7 VI OPERATION INSTRUCTIONS 8 A INITIAL STARTUP 8 A 10 Fill Tanks with Water 8 A 20 Add Soap Chemicals 8 A 30 Approve...

Страница 3: ...umbing codes Before connecting the unit to the electrical supply verify that the electrical and grounding connections comply with the applicable portions of the National Electrical Code and or other l...

Страница 4: ...h Do not operate this equipment without properly placing and securing all covers and access panels Failure to comply with this procedure can cause property damage injury or death Do not use or store g...

Страница 5: ...d sanitizer sink 5 K5000 Control V Indicates the heating element wattage used in the powered wash sink 2 2500 watt 5 5000 watt 7 7000 watt Not available on 208 240 VAC units that have a heated sanitiz...

Страница 6: ...exterior damage on the delivery receipt which must also be signed by the driver delivery person Unpack and check for any damage which was not evident on the outside of the shipping container Check for...

Страница 7: ...16 Pan Rack Adjustable 28 Wide by 72 Long Unit 115822 17 Pan Rack Drop in 115891 18 Basket Skewer 115833 19 Basket Utensil 115653 DRAIN EXTRA TUBING USED ON 60 72 TANKS ONLY COUPLES ELBOW WASH TANK O...

Страница 8: ...y add the soap into the wash tank in accordance with the chemical supplier s instructions Soap Pump Installation SANITIZETANK Ifequipped addtheappropriate sanitizing chemical to the sanitize tank Cons...

Страница 9: ...placed in a utensil basket If your unit was not supplied with a utensil basket one can be ordered from the factory Contact information is provided in the Customer Assistance section of this manual To...

Страница 10: ...a holding cycle This cycle has slower water movement that will keep grease and soiled sediments from falling back onto the items that were just cleaned Remove the clean items from the wash tank and d...

Страница 11: ...n while not in the temperature set point mode will display the time remaining before a mandatory water change Pressing this button while in the temperature set point mode will lower the temperature se...

Страница 12: ...be different from your display Use the Up or Down buttons to change the temperature setting Once set press the TEMP button to lock in the new value NOTE If no button is pressed within three seconds th...

Страница 13: ...it Selection Default Temperature Units is Fahrenheit F The and buttons are used to increment and decrement parameters The TEMP button is used to scroll through the parameters Pressing the TEMP button...

Страница 14: ...the Up and Down button to change the parameters value Once a value has been changed press the TEMP key to lock in this value and move on to the next parameter NOTE If you do not press the TEMP button...

Страница 15: ...r 1 Change Water Cycle Time 4 00 4 00 H MM Timer 2 Soap Dispensing Delay Time 0 45 2 00 M SS Timer 3 Soap Dispensing Time 1 30 0 30 M SS Alarm 1 Alarm 1 Set Point 250 F 107 C Degrees Hysteresis Alarm...

Страница 16: ...2 F Degrees P3 High scale range of sensors 282 C 540 F Degrees P4 Output 1 control action rEu rEu P5 Output 2 function I I P6 Output 2 alarm type H A H A P8 Alarm 1 standby function OFF OFF P11 Auto r...

Страница 17: ...the soap dispensing process Display Software Version To display the software version enter the configuration mode SeeinstructionslistedintheConfigurationMode CnF section listed above When CnF display...

Страница 18: ...cel Button Continuous press will canel active recipes and change to idle screen below Recipe Start Button Touch to start selected recipe Sanitizer Start Button If equipped press play to start the sani...

Страница 19: ...omatically transition to the main off screen Figure Boot Screen Figure Main Screen 2 Touch a recipe button 3 Allow to the sink to test validate the wash water is full at a safe Figure Ready Screen Wat...

Страница 20: ...the Recipe Start Button is pressed the current recipe count down timer will display with a progress bar shown below Figure Recipe Active Screen 2 When the recipe is complete the K 5000 will beep twic...

Страница 21: ...ATION OVERVIEW Figure Status Bar Access the Special Functions PIN Code Entry Screen by selecting the info button on the status bar Enter the PIN Code which corresponds to the desired special function...

Страница 22: ...2 Touch the button for the recipe you to edit i e 3 The recipe edit screen displays the option for 6 stages Stages that are highlighted blue are used in the total recipe Figure Special Functions Scre...

Страница 23: ...ghlighted blue are used in the total recipe Figure Edit Recipe Name Screen CONFIG CONFIGURATIONS 1 Touch the button and then enter pin code 2 3 4 5 and touch the button 2 Touch the button for the sett...

Страница 24: ...lay screen PERFORMANCE MAINTENANCE To access the Special Functions touch button on the Main Tool Bar Figure Status Bar 1 Touch the button enter pin code 4 5 6 7 and touch the button Figure Tools Scree...

Страница 25: ...are individuals firms companies or corporations who are knowledgeable in and responsible for compliance with jurisdiction authorities concerning service of commercial food preparationequipment Contac...

Страница 26: ...Installation and Operation of X STREAM WASH 26 VI ELECTRICAL SCHEMATICS K1000 208 240V 1 PHASE UNITS AFTER 12 2013...

Страница 27: ...27 Installation and Operation of X STREAM WASH K1000 208 240V 1 PHASE UNITS TO 12 2013...

Страница 28: ...Installation and Operation of X STREAM WASH 28 K1000 208 240V 3 PHASE UNITS AFTER 12 2013...

Страница 29: ...29 Installation and Operation of X STREAM WASH K1000 208 240V 3 PHASE UNITS TO 12 2013...

Страница 30: ...Installation and Operation of X STREAM WASH 30 K1000 440 480V 3 PHASE UNITS AFTER 12 2013...

Страница 31: ...31 Installation and Operation of X STREAM WASH K1000 440 480V 3 PHASE UNITS TO 12 2013...

Страница 32: ...USB S1 SC A1 AC S L2 T L3 R L1 U T1 V T2 W T3 Variable Fq Drive T couples Dry Fire Wash Water Temp CHEM PUMP 1 WASH PUMP 1 WASH PUMP 2 WD DMC K5000 208 240V Duke Mfg NPD StL 3 2 17 ts Front Cover P1 P...

Страница 33: ...nal USB S1 SC A1 AC S L2 T L3 R L1 U T1 V T2 W T3 Variable Fq Drive T couples Dry Fire Wash Water Temp CHEM PUMP 1 WASH PUMP 1 WASH PUMP 2 WD DMC K5000 480V Duke Mfg NPD StL 3 2 17 ts Front Cover P1 P...

Страница 34: ...Installation and Operation of X STREAM WASH 34 K5000 208 240V 3 PHASE W SANITIZER...

Страница 35: ...35 Installation and Operation of X STREAM WASH K5000 420 480V 3 PHASE W SANITIZER...

Страница 36: ...Installation and Operation of X STREAM WASH 36 Duke Manufacturing Co 2305 N Broadway St Louis MO 63102 Phone 314 231 1130 Toll Free 1 800 735 3853 Fax 314 231 5074 www dukemfg com...

Отзывы: