Setup Mode – 

OP.S

Enter the supervisor mode and press the 

Up 

or 

Down 

buttons until OP.5 appears in the display. 

Press the 

TEMP 

button to select.

When prompted for a password PSS and three dashes 

toggle. The three dashes is where you enter the 

password of 55.

    

Use the 

Up 

and 

Down 

buttons to select 55.

Press the 

TEMP 

button to enter and lock the password 

and advance.

Press the 

TEMP 

button to advance between the 

parameters that are available, see parameter table.

(The parameter name and its value will be swapped 

in and out of the display.) 
Press the 

Up 

and 

Down 

button to change the 

parameters value.

Once a value has been changed, press the 

TEMP 

key 

to lock in this value and move on to the next parameter. 

NOTE:

  If you do not press the 

TEMP 

button within 3 

seconds after changing a parameters value, 

the new value will not be saved. Push 

TEMP

 

button to access parameters again.

          IMPORTANT          

Before  you  save  and  exit,  you  need  to  scroll 

through the parameters back to the temp display 

before pressing the 

Temp

 and 

Start/Stop

 buttons 

simultaneously.

To save and exit the supervisor mode, press 

TEMP 

and 

START/STOP 

buttons simultaneously for 3 

seconds and OPr appears in the display. 

Press the 

Down 

button once and OP.b appears in 

the display. 

Then press the 

TEMP 

button and FIL appears in the 

display and you have exited the supervisor mode

.

Содержание X-STREAM WASH

Страница 1: ...is Copyright 2017 Duke Manufacturing Co All rights reserved Reproduction without written permission is prohibited Duke is a registered trademark of the Duke Manufacturing Co Duke Manufacturing Co 2305...

Страница 2: ...MENT 6 D PLUMBING REQUIREMENTS 6 E ELECTRICAL CONNECTIONS 7 F XSTREAM WASH OPTIONS 7 VI OPERATION INSTRUCTIONS 8 A INITIAL STARTUP 8 A 10 Fill Tanks with Water 8 A 20 Add Soap Chemicals 8 A 30 Approve...

Страница 3: ...umbing codes Before connecting the unit to the electrical supply verify that the electrical and grounding connections comply with the applicable portions of the National Electrical Code and or other l...

Страница 4: ...h Do not operate this equipment without properly placing and securing all covers and access panels Failure to comply with this procedure can cause property damage injury or death Do not use or store g...

Страница 5: ...d sanitizer sink 5 K5000 Control V Indicates the heating element wattage used in the powered wash sink 2 2500 watt 5 5000 watt 7 7000 watt Not available on 208 240 VAC units that have a heated sanitiz...

Страница 6: ...exterior damage on the delivery receipt which must also be signed by the driver delivery person Unpack and check for any damage which was not evident on the outside of the shipping container Check for...

Страница 7: ...16 Pan Rack Adjustable 28 Wide by 72 Long Unit 115822 17 Pan Rack Drop in 115891 18 Basket Skewer 115833 19 Basket Utensil 115653 DRAIN EXTRA TUBING USED ON 60 72 TANKS ONLY COUPLES ELBOW WASH TANK O...

Страница 8: ...y add the soap into the wash tank in accordance with the chemical supplier s instructions Soap Pump Installation SANITIZETANK Ifequipped addtheappropriate sanitizing chemical to the sanitize tank Cons...

Страница 9: ...placed in a utensil basket If your unit was not supplied with a utensil basket one can be ordered from the factory Contact information is provided in the Customer Assistance section of this manual To...

Страница 10: ...a holding cycle This cycle has slower water movement that will keep grease and soiled sediments from falling back onto the items that were just cleaned Remove the clean items from the wash tank and d...

Страница 11: ...n while not in the temperature set point mode will display the time remaining before a mandatory water change Pressing this button while in the temperature set point mode will lower the temperature se...

Страница 12: ...be different from your display Use the Up or Down buttons to change the temperature setting Once set press the TEMP button to lock in the new value NOTE If no button is pressed within three seconds th...

Страница 13: ...it Selection Default Temperature Units is Fahrenheit F The and buttons are used to increment and decrement parameters The TEMP button is used to scroll through the parameters Pressing the TEMP button...

Страница 14: ...the Up and Down button to change the parameters value Once a value has been changed press the TEMP key to lock in this value and move on to the next parameter NOTE If you do not press the TEMP button...

Страница 15: ...r 1 Change Water Cycle Time 4 00 4 00 H MM Timer 2 Soap Dispensing Delay Time 0 45 2 00 M SS Timer 3 Soap Dispensing Time 1 30 0 30 M SS Alarm 1 Alarm 1 Set Point 250 F 107 C Degrees Hysteresis Alarm...

Страница 16: ...2 F Degrees P3 High scale range of sensors 282 C 540 F Degrees P4 Output 1 control action rEu rEu P5 Output 2 function I I P6 Output 2 alarm type H A H A P8 Alarm 1 standby function OFF OFF P11 Auto r...

Страница 17: ...the soap dispensing process Display Software Version To display the software version enter the configuration mode SeeinstructionslistedintheConfigurationMode CnF section listed above When CnF display...

Страница 18: ...cel Button Continuous press will canel active recipes and change to idle screen below Recipe Start Button Touch to start selected recipe Sanitizer Start Button If equipped press play to start the sani...

Страница 19: ...omatically transition to the main off screen Figure Boot Screen Figure Main Screen 2 Touch a recipe button 3 Allow to the sink to test validate the wash water is full at a safe Figure Ready Screen Wat...

Страница 20: ...the Recipe Start Button is pressed the current recipe count down timer will display with a progress bar shown below Figure Recipe Active Screen 2 When the recipe is complete the K 5000 will beep twic...

Страница 21: ...ATION OVERVIEW Figure Status Bar Access the Special Functions PIN Code Entry Screen by selecting the info button on the status bar Enter the PIN Code which corresponds to the desired special function...

Страница 22: ...2 Touch the button for the recipe you to edit i e 3 The recipe edit screen displays the option for 6 stages Stages that are highlighted blue are used in the total recipe Figure Special Functions Scre...

Страница 23: ...ghlighted blue are used in the total recipe Figure Edit Recipe Name Screen CONFIG CONFIGURATIONS 1 Touch the button and then enter pin code 2 3 4 5 and touch the button 2 Touch the button for the sett...

Страница 24: ...lay screen PERFORMANCE MAINTENANCE To access the Special Functions touch button on the Main Tool Bar Figure Status Bar 1 Touch the button enter pin code 4 5 6 7 and touch the button Figure Tools Scree...

Страница 25: ...are individuals firms companies or corporations who are knowledgeable in and responsible for compliance with jurisdiction authorities concerning service of commercial food preparationequipment Contac...

Страница 26: ...Installation and Operation of X STREAM WASH 26 VI ELECTRICAL SCHEMATICS K1000 208 240V 1 PHASE UNITS AFTER 12 2013...

Страница 27: ...27 Installation and Operation of X STREAM WASH K1000 208 240V 1 PHASE UNITS TO 12 2013...

Страница 28: ...Installation and Operation of X STREAM WASH 28 K1000 208 240V 3 PHASE UNITS AFTER 12 2013...

Страница 29: ...29 Installation and Operation of X STREAM WASH K1000 208 240V 3 PHASE UNITS TO 12 2013...

Страница 30: ...Installation and Operation of X STREAM WASH 30 K1000 440 480V 3 PHASE UNITS AFTER 12 2013...

Страница 31: ...31 Installation and Operation of X STREAM WASH K1000 440 480V 3 PHASE UNITS TO 12 2013...

Страница 32: ...USB S1 SC A1 AC S L2 T L3 R L1 U T1 V T2 W T3 Variable Fq Drive T couples Dry Fire Wash Water Temp CHEM PUMP 1 WASH PUMP 1 WASH PUMP 2 WD DMC K5000 208 240V Duke Mfg NPD StL 3 2 17 ts Front Cover P1 P...

Страница 33: ...nal USB S1 SC A1 AC S L2 T L3 R L1 U T1 V T2 W T3 Variable Fq Drive T couples Dry Fire Wash Water Temp CHEM PUMP 1 WASH PUMP 1 WASH PUMP 2 WD DMC K5000 480V Duke Mfg NPD StL 3 2 17 ts Front Cover P1 P...

Страница 34: ...Installation and Operation of X STREAM WASH 34 K5000 208 240V 3 PHASE W SANITIZER...

Страница 35: ...35 Installation and Operation of X STREAM WASH K5000 420 480V 3 PHASE W SANITIZER...

Страница 36: ...Installation and Operation of X STREAM WASH 36 Duke Manufacturing Co 2305 N Broadway St Louis MO 63102 Phone 314 231 1130 Toll Free 1 800 735 3853 Fax 314 231 5074 www dukemfg com...

Отзывы: