Installation and Operation of X-STREAM WASH
12
K-1000
Basic Operation
When you first power up to use your wash tank, the
display will show FIL, fill the wash tank to the water fill
line (see the INITIAL STARTUP section).
Once the tank has been filled, press the
START/STOP
button to start the continuous wash cycle. Soap will be
dispensed automatically into the wash tank.
During the wash operation, the display will show current
water temperature and the heater light will cycle on
and off as the heater is maintaining the preset water
temperature.
The
START/STOP
button can be used to toggle on
and off the circulation pumps. During a pause state,
the heater is still in operation and maintaining the water
temperature.
After a certain amount of time, the water is considered
dirty and the circulation pumps will turn off, the display
will show drn, and the change water indicator light will
flash.
NOTE:
Pressing the
Down Arrow
key will display
the time remaining before a water change is
required.
After the water has been drained, the display will
show FIL. You are now ready to start another wash
cycle.
Changing Temperature Set Point
The temperature set point is the water temperature
setting for the wash tank and is the only parameter
that can be set by the operator. If the
TEMP
button is
pressed once, the display will switch back and forth
from SP and 115 (115 represents the temperature
setting and may be different from your display).
Use the
Up
or
Down
buttons to change the temperature
setting. Once set, press the
TEMP
button to lock in the
new value.
NOTE:
If no button is pressed within three seconds,
then your display will revert back to the way
it was before the
TEMP
button was pressed.
If the temperature setting was changed and
the
TEMP
button was not pressed, then the
temperature setting will remain unchanged.
Reset Change Water
The Change Water flag is cleared whenever the
heater’s sheath temperature rises above its set point.
In the case of a heater failure this flag cannot be reset
automatically. To manually reset this flag you will need
to hold down the
Up
button and
START/STOP
button
simultaneously for approximately 15 seconds. The
controller will then enter the
FIL state.
Temperature Sensor Fault
If the water or heater sheath temperature sensors should
fail, the controller will indicate the fault by taking the
controller to the
FIL
state. The alarm light will be on,
the heater will be disabled, and the circulation pump
will be off.
After the sensor(s) have been replaced, normal
operation is resumed by exiting the
FIL state.
Alarms
Alarm 1 is associated with the heater’s sheath
temperature, and is triggered when the temperature
rises above the value set in
AL.1 (see chart above).
Alarm 2 is associated with the wash tanks water
temperature, and is triggered when the temperature
rises above the value set in
AL.2 (see chart above).
When one of these alarms is activated, the circulation
pump will turn off and the alarm indicator light will be
illuminated. The controller will enter the
FIL state.
Содержание X-STREAM WASH
Страница 27: ...27 Installation and Operation of X STREAM WASH K1000 208 240V 1 PHASE UNITS TO 12 2013...
Страница 28: ...Installation and Operation of X STREAM WASH 28 K1000 208 240V 3 PHASE UNITS AFTER 12 2013...
Страница 29: ...29 Installation and Operation of X STREAM WASH K1000 208 240V 3 PHASE UNITS TO 12 2013...
Страница 30: ...Installation and Operation of X STREAM WASH 30 K1000 440 480V 3 PHASE UNITS AFTER 12 2013...
Страница 31: ...31 Installation and Operation of X STREAM WASH K1000 440 480V 3 PHASE UNITS TO 12 2013...
Страница 34: ...Installation and Operation of X STREAM WASH 34 K5000 208 240V 3 PHASE W SANITIZER...
Страница 35: ...35 Installation and Operation of X STREAM WASH K5000 420 480V 3 PHASE W SANITIZER...