Page 42
iQ Series AiM
™
Automation in Mind
,
Ultrasonic Power Supply User’s Manual
Dukane Manual Part No. 403-610-02
System Test
To test the system’s ultrasound operation, perform the
following steps.
1. For this test, the generator must be ONLINE. Make
sure ONLINE appears in the upper right corner of the
display.
2. Connect a probe to the generator ultrasonic output.
3. Place the probe so that the tip of horn is not in contact
with anything. If you are using a hand probe, you may
feel a slight vibration or sensation in your hand. This
is normal. There should not be any loud or unusual
noise.
4. Navigate to the Real Time Data screen
5. Press and hold the
TEST
key (
A
in Figure 4-18).
6. The first segment
LED
of the
SYSTEM POWER
OUTPUT LEVEL
bar graph (
B
in Figure 4-19) turns
red. The probe will operate as long as the
TEST
key is
pressed.
7. When the
TEST
key is released, the
SYSTEM POW-
ER OUTPUT LEVEL
bar graph turns off (no red in
the bar graph area). This test cannot be performed
with the generator
OFFLINE
.
CAUTION
Any unusually loud noise
from the probe stack in-
dicates that it has been
improperly assembled.
Check the probe stack
for correct assembly and
proper torque.
Figure 4 - 19
System Test
A
B
Figure 4 - 18
Test Key