11.3 Hook Shaft Height
The clearance between the needle plate support 4 and the shoulder 1
of the hook shaft must be 17.7 mm.
The precise height of the hook shaft is set with the gauge 3
(Order no. 244 001001).
Caution Risk of Injury !
Turn the main switch off.
Set the hook shaft height only with the main switch turned off.
–
Remove the needle plate.
–
Remove both hooks (see Chapter 11.9).
–
Place gauge 3 on the needle plate support 4.
The measuring sleeve 2 of the gauge must catch over the peg of
the hook shaft.
–
Tilt the machine head to the back.
–
Remove oil baffles 7 after loosening the mounting screws.
–
Remove the plastic plugs 6.
Loosen the screws found under the plastic plugs.
–
Loosen screws 5.
–
Remove the pressure pins 8.
–
Push the hook shaft with its shoulder 1 until under the measuring
sleeve 2 of the gauge.
–
In this position tighten the screws found under the plastic plugs 6.
–
Slide the pressure pins 8 up to the stop against the hook shaft.
–
Tighten screws 5 on the surfaces the pressure pins 8.
–
Attach the oil baffles 7, hook and needle plate again.
1 2 3 4
7 8
5 6