3.3 Position of the Folder to the Needles and the Center Knife
With a properly mounted folder the following positions must be
attained:
–
In the most forward position the needles must enter the needle
holes of the folder sole unhindered (without being deflected).
–
When the center knife 1 enters the knife guard 2 in the most
forward position there must still be a clearance of 0.5 to 1 mm
between the front edge of the knife and knife guard.
Caution Risk of Injury !
Turn the main switch off.
Align the folder to the needles and the center knife only with the main
switch turned off.
To correct:
–
Loosen screws 3 slightly.
–
Slide the folder in the direction of transport.
–
Tighten screws 3 again.