3.1 Stroke Movement of the Folder
Caution Risk of Injury !
Turn the main switch off.
Set the stroke movement of the folder only with the main switch turned
off.
With the folder raised:
There must be a safety clearance of 3 mm between the lever 13 and
the bottom of the curve piece 12.
–
Loosen nut 6.
–
Set the mounting of the cylinder 7 higher or lower accordingly.
–
Tighten nut 6.
With the folder lowered:
The clearance between the folder sole and the cloth slider plate must
be 2 mm along the whole length.
–
Loosen nut 10.
–
Set the clearance between the bottom of folder sole and the cloth
slider plate by turning the piston rod of the cylinder 7.
–
If the roller lays on in the lowest point of the curve path 8:
Loosen screws 11.
Set the curve piece 12 lower.