Caution Risk of Injury !
Danger of cuts!
When working on the needle holders 5 do not reach into the area of
the center knife 9.
–
Press under the needle holder 5 of the needle bar to be turned off.
At the same time turn the handwheel backwards.
The needle bar is turned off.
–
Bring the needle bar into the looping stroke position
(see Chapter 11.5).
–
Insert the arresting pin 10 through the drilled hole in the machine
arm.
The arresting pin 10 must catch in the groove of the arm shaft
crank.
–
Push the setting pin 6 into the needle holder 5 up to the stop.
–
Tighten screw 13.
–
Screw screw 11 out.
–
Turn needle holder 5 downward.
It should be possible to push the measuring bridge 4 under the
setting pin 6 with the least possible play.
–
If necessary, turn the needle holder 5 back (higher) accordingly.
The front surfaces 12 of the needle holder 5 must hereby face
forward and lie at one level.
–
Screw in screw 11 in the needle holder 5 and tighten.
–
Remove arresting pin 10 and setting pin 6.
–
Remove spacer 3.