9.1 Clearance of the flap clamps to the slider plate
If the sewing unit is equipment with flap clamps 0791 011161 (clamp
left) and/or 0792 011162 (clamp right), the clearance of the flap clamps
to the cloth slider plate should be 40 mm.
1: Flap clamp
2: Slider plate
3: Transport clamp
4: Center of the pocket
opening
Caution Risk of Injury !
Turn the main switch off.
Set the flap clamps only with the main switch turned off.
–
Losen screw 5.
–
Set stop 6.
The clearance of the flap clamps to the cloth slider plate should be
40 mm.
–
Tighten srew 5 again.
10. Synchronizer
It is practical to first set the 2nd needle position.
2nd needle position: Needle high position
With the needle bars turned off in the highest position the thread lever
must position 2 mm behind its upper dead center.
–
Turn the main switch off.
–
Bring the thread lever into a central position by turning the
handwheel.
–
Turn the main switch on.
The sewing unit positions in the needle high position (Position 2).
–
Check the position of the thread lever.
If necessary, correct the positioning.
Caution Risk of Injury !
Turn the main switch off.
Correct the positioning only with the main switch turned off.
–
Loosen clamping screws 2 on the synchronizer collar 1.
–
Hold the synchronizer collar 1.
–
Move the thread lever 2 mm behind its upper dead center by
turning the handwheel.
–
Tighten the clamping screws 2.
–
Check the positioning again.
1
2 3 4
5
6
36
Содержание 745-22
Страница 17: ...8 7 6 5 1 2 3 4 17 ...
Страница 19: ...1 2 3 4 7 8 9 10 5 6 19 ...
Страница 25: ...745 22 745 23 745 24 5 4 3 4 3 4 25 ...
Страница 27: ...745 22 745 23 745 24 7 9 2 6 5 7 9 1 2 3 4 5 6 7 8 9 5 mm 10 11 12 13 14 15 27 ...
Страница 43: ...1 2 3 4 5 6 7 8 0 2 mm 9 10 43 ...
Страница 79: ...2 3 4 5 y 7 1 8 6 9 10 1 2 3 4 5 79 ...