12
DUCATI
actuator model HC418
Installation diagram
HC418
HC418 FC (with on board open& closed position
mechanical limits)
each model is also available in 24V version
PUSH TO OPEN OPERATION (opens towards outside)
If your driveway slopes up after the gate, preventing it from swin-
ging in. This means the gate operator is mounted on the inside
of the property and pushes your gate out away from the property.
Warning: only compatible with telescopic tube actuators, Check
the overall dimensions before installation
.
Warning:remember to reverse the polarity of the motor cables
when connecting to the electronic board
maximal
dimension
A=10 cm
A=12cm
A=14 cm
A=18 cm
B= 10cm
108°
115°
120°
100°
B= 12cm
105°
112°
100°
100°
B= 14cm
103°
109°
98°
/
B= 16cm
101°
97°
90°
/
B= 18cm
97°
/
/
/
720 mm
100 mm
160 mm
D = 6cm
D = 8,5cm
D = 10cm
D = 2,5cm
D = 2,5cm
D = 5,4cm
Supplied fixing braket:
choose the hole most suitable to your gate.
You can cut the plate if necessary
Maximal wing dimension:
Maximal wing lenght: up to 2m/ 6,5 ft
Maximal wing weight: up to 200kg/ 440lb
180 -560 mm
NOT POSSIBLE WITH THIS ACTUATOR MODEL: IT REQUIRES TELESCOPIC ACTUATORS
METRIC CONVERSION
1 cm = 1⁄2
”
= 0,3
”
10 cm = 4
”
12 cm = 4
3⁄4”
= 4,7
”
14 cm = 5
1⁄2”
= 5,5“
16 cm = 6
1⁄5”
= 6,2
”
18 cm = 7
”
PULL TO OPEN OPERATION ( opens towards inside)
This means the gate operator is mounted on the inside of the property
and pulls your gate in towards the property to open.
OUTSIDE
Rear pivot point of gate opener
In line with center hinge
INSIDE