Connections and adjustments:
ATTENTION ! all settings have to be made with gate in closed position
CONNECTORS:
1/3 (STR) START contact NO full cycle opening
2 (FTC) Photocell NC contact (FTC)
3 (COM) Common ( start &photocell)
4 (POS) + power photocell positive 12V dc
3 - power photocell negative
5 M1 actuator brown cable
6 M1 actuator blue cable
7 M2 actuator brown cable
8 M2 actuator blue cable
9/10 12V 10W max. blinking light
Photocells bridge: between connectors 2/3
Remove the bridge only when connecting the photocells.
The phase shift between the 2 wings is automatically set and can not be modified.
RED LED =
steady on while the door is open or closed= step by stepoperating mode is set.
blinking while the gate is open= automatic pause time counting before the gate re-closes.
also used as indicator during the remote control memorizing procedure
Fusibile : a ripristino automatico
Transformer imput= 0 (black cable) 12V (Yellow cable)
PUSH BUTTON:
P1 = FULL CYCLE push button to store or cancel the radio transmitters codes on the electronic board.
This button is used to set complete opening cycles. Red LED visual indicator.
HOW TO MEMORIZE/ DELETE REMOTE CONTROL CODE IN THE
ELECTRONIC BOARD ( see also remote control chapter)
Remote controls setting: to syncronize a remote control channel:
On the main board Press P1 to memorize a remote control Channel for compleete opening cycle.
Release P1.
As the red LED turns on, push the selected radio remote control button. After the red LED blinks, wait until
the red LED turns off. Operation completed.
Maximal storage capacity: 10 channels
To delete the stored channels press P1 for about 30 sec. until the red LED turns off.
All remote control codes will be delated.
OPERATING MODE: STEP BY STEP or AUTOMATIC
the electronic board is set on “STEP by STEP” working mode.
with this setting a pulse controls the opening and a second impulse closes the gate.
How to set the automatic closure function(the pause time before the gates automatically closes is
30seconds and cannot be adjusted):
1- cut off the power to the board and wait for 5 seconds
2- keeping P1 key pressed, power the board.
the red LED will switch on
Operation performed.
Following the same procedure you will return to the step by step operating mode.
CTH41 MONO
special version for use on single wing gate: only connect M1. Ohter connections remain the same
CTH41
0
12V
trasformer
230(110V)
0,8A
T (1,2A
T)
M1
M2
STR
FTC
COM
POS
START
FTC
NC