36
-
to 12V batt
-
0= step
by step
max100 sec.
automatic
closure
SENS
TIME
0
12V
transformer
230(110V)
0,8A
T (1,2A
T)
START
Pedestrian
FUSE
Solar panel
12V
START
full cycle
+12V -
photocell
FTC
NC
12V dc
electrolock output
Booster
switch
CTH48
T1
T2
T3
12V 10W
blinking light
M1
M2
STOP
-
-
+
+
switch 1
:
ON
OFF
switch 2
:
FAST
ON
OFF
switch 3
:
ON
OFF
Keep
OPEN
switch 4
:
GARDEN
LIGHT
ON
OFF
STATUS
AC
RELAYS
A)
Garden courtesy
timerized light 12V
max 10W
B)
Garden courtesy timeri-
zed light powered by 230V
/110V
K
10AT
5 x 20
DEEP SWITCHES
see next page for detailed instructions
ANTI
Theft
GATE STATUS remo-
te indicator light 12V
max 10W lamp
ATTENTION:
USE OF PHOTOCELLS ON CTH48
It is highly recommended to use original DUCATI photocells only.
Use only low consumption photocells model 7120 in case of solar
panel power supply.
It is recommended to use photocells model DUCATI 7012
in case of standard supply by 230/110 V
For different needs first contact our technical department
before connecting any non original photocells model.
electrolock
RX
(photocell model 7012 receiver)
3 (COM) common connect to n° 7 on CTH48
4 FTC (photocell contact NC) connect to n° 6 on CTH48
RX
(photocell model 7120 receiver)
1 (+) connect to
n° 9 on CTH48
2 (-) connect to
n° 10 on CTH48
TX (photocell transmitter
Same for both 7120 & 7012
4 not to be used
1 (+) connect to n° 9 on CTH48
2 (-) connect to n° 10 on CTH48
Attention: If photocells are connected take
out the photocells bridge between connectors
6 & 7
1 (+) connect to n° 9 on CTH48 on 9
2 (-) connect to n° 10 on CTH48
3 FTC (photocell contact NC) connect to n° 6 on CTH48
D U C A T I
E l e c t r o n i c b o a r d
C T H 4 8
To deactivate
SOFT STOP &
Obstcle reversal
system
To activate
SOFT STOP &
Obstcle reversal
system
Use on 2 wings
gate
Use on 1 wing gate
SLOW/ ARS
WARNING: start installation with potentiometers
positioned as follows:
TIME: rotated anticlockwise
SENS: rotated clockwise
SLOW: rotated anticlockwise