background image

                 

 

                                         

SLIDING GATE OPERATOR

 

 

USER’S MANUAL   

 

 

MODEL: L200Y 

 

 

 

 

 

 

 

 

                     

 

 

 

 

 

 

         

 

 

 

 

 

 

 

WARNING! 

ONLY QUALIFIED AND EXPERIENCED TECHNICIANS 

SHOULD  ATTEMPT  INSTALLATION  OR  SERVICE  TO 

THIS  UNIT,  OTHERWISE,  SERIOUS  PERSONAL 

INJURY,  DEATH,  OR  PROPERTY  DAMAGE  MAY 

OCCUR. 

PLEASE 

KEEP 

THESE 

INSTRUCTIONS 

FOR 

FURTHER REFERENCE.

 

Total Door Automation (Australia) Pty Ltd 

www.totaldoorautomation.com.au 

[email protected] 

 

 

 

 

 

Содержание L200Y

Страница 1: ...ECHNICIANS SHOULD ATTEMPT INSTALLATION OR SERVICE TO THIS UNIT OTHERWISE SERIOUS PERSONAL INJURY DEATH OR PROPERTY DAMAGE MAY OCCUR PLEASE KEEP THESE INSTRUCTIONS FOR FURTHER REFERENCE Total Door Auto...

Страница 2: ...S MANUAL 2 OUTLINE 1 Important safety information 3 2 Main features 3 3 Technical parameters 3 4 Working principle and main structure 4 5 Installation and adjustment 5 6 Electrical 8 7 Control 11 8 Ma...

Страница 3: ...trol devices to be placed so that a person can access them by reaching through the gate In the event of power failure an emergency release key allows you to operate the gate manually The operator shou...

Страница 4: ...ushes rack attached to the sliding gate thus moving the gate The dimension is shown in Fig 1 Fig 1 The structure of the motor and worm is shown in Fig2 Output torque can be adjusted by pressure screw...

Страница 5: ...essure nut Mandrel Key Gear clutch Worm gear Fig 3 The device is equipped with a thermal protector the thermal protector will switch off the motor automatically in case of temperature is higher than 9...

Страница 6: ...se the anchor bolts anchors washers and nuts These anchors must be set into the concrete when it is poured or you can use wedge anchors Fig 5 Operator Base Mount the gate operator base to the concrete...

Страница 7: ...determine the position Weld the magnet bracket to the rack and then tighten the gear clutch The lower bracket is for open position and higher bracket is for close position Finally adjust the magnet t...

Страница 8: ...6 Electrical Make sure that the power is OFF before making any electrical connections Remove the cover of the control box perform the wiring and replace the cover again Refer to Fig 9 control board s...

Страница 9: ...mit switch CL Close limit CO Com OP Open limit DC12V Output power supply CL COM OP N C For N C limit switch CL COM OP N O For N O limit switch Limit switch mode is adjustable by DIP switch See table 2...

Страница 10: ...three button mode or single button mode you can select according to your order 15 Output power supply 12V DC 12V COM CO DET Loop detector I R Infrared N C DET COM Out COM AC24V AC24V Terminal X5 No 1...

Страница 11: ...nds The learning process is finished Up to 100 remote controls may be used Erase remote controls To erase all existing remote controls press and hold AN button the beeper will ring release the button...

Страница 12: ...ction has been set Cancel auto close function please turn on the first and the second DIP switch see Fig 9 terminal 18 to ON position Press the remote control button button 1 button 2 or button 3 that...

Страница 13: ...IP switch 1 to OFF position immediately Thus the width and auto close function of pedestrian mode have been cancelled Cancel width of pedestrian mode keep auto close function of pedestrian mode Please...

Страница 14: ...the limit direction is wrong Activities Covered in this section Remote control Single button mode With each press of the button the gate will close stop open or stop cycle External button switch not s...

Страница 15: ...w to make the output torque of the operator meet your requirement that is the device should be powerful enough to move the gate and capable of making friction plate skidding when it is blocked The mot...

Страница 16: ...se The limit switch wire connector terminal block becomes loose Check the limit switch mode see table 2 DIP switch Connecting wires or terminal blocks are too loose Check the connecting wires and term...