background image

L200Y SLIDING GATE OPERATOR USER

’S MANUAL 

16 

9.

 

Troubleshooting 

Table 4 

 

 

 

Trouble 

Possible causes 

Solutions 

Motor only runs in one direction. 

The  wire  connector  terminal  block  becomes 

loose.   

Check wire connector terminal block. 

The limit switch wire connector terminal block 

becomes loose. 

Check  limit  switch  wire  connector  terminal 

block. 

Check the limit switch mode. 

By pressing button 1(button 2 or button 

3)  which  has  been  programmed  to 

open  the  gate,  press  the  same  button 

again  to  stop  the  gate  in  required 

position,  but  the  gate  will  auto-close 

immediately. 

The auto-close time is too short. 

Reset  the  auto-close  time.  See

  Set 

auto-close function

 section. 

When  you  use  button  4  of  remote 

control  to  open  the  gate,  gate  travels 

too short.   

The width of pedestrian mode is too narrow. 

Reset the width of pedestrian mode. See 

Set 

width of pedestrian mode 

section. 

When  you  use  button  4  of  remote 

control  to  open  the  gate,  but  the  gate 

will auto-close immediately. 

The  auto-close  time  of  pedestrian  mode  is 

too short. 

Reset the auto-close time of pedestrian. See 

Set  auto-close  function  of  pedestrian 

mode 

section. 

The gate will not open or close. 

The limit switch wire connector terminal block 

becomes loose. 

Check  the  limit  switch  mode  (see  table  2 

DIP-switch). 

Connecting  wires  or  terminal  blocks  are  too 

loose. 

Check  the  connecting  wires  and  terminal 

blocks. 

The electric component on the control board 

such as Q6 may be damaged. 

Replace  the  electric  component  Q6  or 

replace the board. 

Power switch is OFF 

Make sure power switch is ON. 

Remote control does not work 

The indicator light of remote control does not 

light. 

Check the batteries on your remote control 

Remote control is not suitable for receiver.   

After  making  sure  the  codes  are  correct, 

erase  remote  controls  and  then  re-program 

the  codes  in  the  device.  See

  Adding  extra 

remote controls (learning) 

section. 

Broken receive board 

Replace receive board. 

When  you  open  the  gate  by  using 

button  1(button  2  or  button  3)  which 

has been programmed, gate will stop in 

mid-travel  or  reverse  before  reaching 

the fully limit position. 

The Force Adj. (VR) is adjusted too small. 

Check  the  Force  Adj.  (VR).  Adjust  VR  to 

increase force. 

Gate is obstructed. 

Remove the obstruction. 

The  remote  control  operating  distance 

is too short. 

Signals are shielded by the gate. 

Link a new antenna (1~1.2m BVR 0.75mm

2

to  the  old  antenna.  Then  fix  the  antenna  on 

the wall vertically, make sure the total height 

from  the  top  of  antenna  to  the  ground  is 

approx. 1.5m. 

Содержание L200Y

Страница 1: ...ECHNICIANS SHOULD ATTEMPT INSTALLATION OR SERVICE TO THIS UNIT OTHERWISE SERIOUS PERSONAL INJURY DEATH OR PROPERTY DAMAGE MAY OCCUR PLEASE KEEP THESE INSTRUCTIONS FOR FURTHER REFERENCE Total Door Auto...

Страница 2: ...S MANUAL 2 OUTLINE 1 Important safety information 3 2 Main features 3 3 Technical parameters 3 4 Working principle and main structure 4 5 Installation and adjustment 5 6 Electrical 8 7 Control 11 8 Ma...

Страница 3: ...trol devices to be placed so that a person can access them by reaching through the gate In the event of power failure an emergency release key allows you to operate the gate manually The operator shou...

Страница 4: ...ushes rack attached to the sliding gate thus moving the gate The dimension is shown in Fig 1 Fig 1 The structure of the motor and worm is shown in Fig2 Output torque can be adjusted by pressure screw...

Страница 5: ...essure nut Mandrel Key Gear clutch Worm gear Fig 3 The device is equipped with a thermal protector the thermal protector will switch off the motor automatically in case of temperature is higher than 9...

Страница 6: ...se the anchor bolts anchors washers and nuts These anchors must be set into the concrete when it is poured or you can use wedge anchors Fig 5 Operator Base Mount the gate operator base to the concrete...

Страница 7: ...determine the position Weld the magnet bracket to the rack and then tighten the gear clutch The lower bracket is for open position and higher bracket is for close position Finally adjust the magnet t...

Страница 8: ...6 Electrical Make sure that the power is OFF before making any electrical connections Remove the cover of the control box perform the wiring and replace the cover again Refer to Fig 9 control board s...

Страница 9: ...mit switch CL Close limit CO Com OP Open limit DC12V Output power supply CL COM OP N C For N C limit switch CL COM OP N O For N O limit switch Limit switch mode is adjustable by DIP switch See table 2...

Страница 10: ...three button mode or single button mode you can select according to your order 15 Output power supply 12V DC 12V COM CO DET Loop detector I R Infrared N C DET COM Out COM AC24V AC24V Terminal X5 No 1...

Страница 11: ...nds The learning process is finished Up to 100 remote controls may be used Erase remote controls To erase all existing remote controls press and hold AN button the beeper will ring release the button...

Страница 12: ...ction has been set Cancel auto close function please turn on the first and the second DIP switch see Fig 9 terminal 18 to ON position Press the remote control button button 1 button 2 or button 3 that...

Страница 13: ...IP switch 1 to OFF position immediately Thus the width and auto close function of pedestrian mode have been cancelled Cancel width of pedestrian mode keep auto close function of pedestrian mode Please...

Страница 14: ...the limit direction is wrong Activities Covered in this section Remote control Single button mode With each press of the button the gate will close stop open or stop cycle External button switch not s...

Страница 15: ...w to make the output torque of the operator meet your requirement that is the device should be powerful enough to move the gate and capable of making friction plate skidding when it is blocked The mot...

Страница 16: ...se The limit switch wire connector terminal block becomes loose Check the limit switch mode see table 2 DIP switch Connecting wires or terminal blocks are too loose Check the connecting wires and term...