background image

L200Y SLIDING GATE OPERATOR USER

’S MANUAL 

15 

If loop detector detects vehicles when the gate stops, the gate will remain stop until vehicles 

move out of the loop. After vehicles move out of the loop, the gate will close.   

The gate will keep opening if loop detector detects vehicles during opening. After  vehicles 

pass through the loop, the gate will close. 

 

Limit  switch:

  The  switch  is  used  to  accurately  stop  the  gate  in  the  opened  and  closed 

positions.

 

If the gate stops at opened position when the limit switch is reached, the gate will not move 

if you press 

‘OPEN’ button. 

If the gate stops at closed position when the limit switch is reached, the gate will not move if 

you press 

‘CLOSE’ button. 

 

Adjust the pressure screw to make the output torque of the operator meet your requirement, 

that  is,  the  device  should  be  powerful  enough  to  move  the  gate  and  capable  of  making 

friction plate skidding when it is blocked. 

 

The motor is only designed to work for less than 5 minutes. If is runs continually for an 

extended period of time, a thermal protector will stop it because of the high temperature.

 

 

8. Maintenance: 

Please check and add transformer oil (DB25-GB2536) regularly, you may change the oil 

according the weather. If the temperature is lower than 

–20

º

C, you can select #45 oil. 

Table 3 Parameters of DB25 transformer oil 

Kinematic viscosity (20

º

C) 

Break down voltage 

Solidification point 

30 Centistoke 

35 kV 

-25

º

 

Ensure the operator is well earthed, and correctly terminated. 

Regularly grease the wheels and axles to ensure the gate moves smoothly. 

Ensure the power is switched off before removing the cover. 

Keep operator clean at all times. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание L200Y

Страница 1: ...ECHNICIANS SHOULD ATTEMPT INSTALLATION OR SERVICE TO THIS UNIT OTHERWISE SERIOUS PERSONAL INJURY DEATH OR PROPERTY DAMAGE MAY OCCUR PLEASE KEEP THESE INSTRUCTIONS FOR FURTHER REFERENCE Total Door Auto...

Страница 2: ...S MANUAL 2 OUTLINE 1 Important safety information 3 2 Main features 3 3 Technical parameters 3 4 Working principle and main structure 4 5 Installation and adjustment 5 6 Electrical 8 7 Control 11 8 Ma...

Страница 3: ...trol devices to be placed so that a person can access them by reaching through the gate In the event of power failure an emergency release key allows you to operate the gate manually The operator shou...

Страница 4: ...ushes rack attached to the sliding gate thus moving the gate The dimension is shown in Fig 1 Fig 1 The structure of the motor and worm is shown in Fig2 Output torque can be adjusted by pressure screw...

Страница 5: ...essure nut Mandrel Key Gear clutch Worm gear Fig 3 The device is equipped with a thermal protector the thermal protector will switch off the motor automatically in case of temperature is higher than 9...

Страница 6: ...se the anchor bolts anchors washers and nuts These anchors must be set into the concrete when it is poured or you can use wedge anchors Fig 5 Operator Base Mount the gate operator base to the concrete...

Страница 7: ...determine the position Weld the magnet bracket to the rack and then tighten the gear clutch The lower bracket is for open position and higher bracket is for close position Finally adjust the magnet t...

Страница 8: ...6 Electrical Make sure that the power is OFF before making any electrical connections Remove the cover of the control box perform the wiring and replace the cover again Refer to Fig 9 control board s...

Страница 9: ...mit switch CL Close limit CO Com OP Open limit DC12V Output power supply CL COM OP N C For N C limit switch CL COM OP N O For N O limit switch Limit switch mode is adjustable by DIP switch See table 2...

Страница 10: ...three button mode or single button mode you can select according to your order 15 Output power supply 12V DC 12V COM CO DET Loop detector I R Infrared N C DET COM Out COM AC24V AC24V Terminal X5 No 1...

Страница 11: ...nds The learning process is finished Up to 100 remote controls may be used Erase remote controls To erase all existing remote controls press and hold AN button the beeper will ring release the button...

Страница 12: ...ction has been set Cancel auto close function please turn on the first and the second DIP switch see Fig 9 terminal 18 to ON position Press the remote control button button 1 button 2 or button 3 that...

Страница 13: ...IP switch 1 to OFF position immediately Thus the width and auto close function of pedestrian mode have been cancelled Cancel width of pedestrian mode keep auto close function of pedestrian mode Please...

Страница 14: ...the limit direction is wrong Activities Covered in this section Remote control Single button mode With each press of the button the gate will close stop open or stop cycle External button switch not s...

Страница 15: ...w to make the output torque of the operator meet your requirement that is the device should be powerful enough to move the gate and capable of making friction plate skidding when it is blocked The mot...

Страница 16: ...se The limit switch wire connector terminal block becomes loose Check the limit switch mode see table 2 DIP switch Connecting wires or terminal blocks are too loose Check the connecting wires and term...

Отзывы: