Страница 2: ...he emergency release only when the road barrier is not moving 6 KEEP THE BARRIER PROPERLY MAINTAINED Read the installation manual and have a qualified service person make repairs to the road barrier h...

Страница 3: ...rned freight prepaid to CAME AMERICAS AUTOMATION LLC 11345 NW 122nd Street Medley Florida 33178 IMPORTANT Obtain a Return Goods Authorization RGA number before returning item s to our facilities by su...

Страница 4: ...NG WITHOUT LIMITATION ANY LIABILITY FOR THIRD PARTY CLAIMS AGAINST YOU FOR DAMAGES THE CUSTOMER ACKNOWLEDGES THAT THIS LIMITED WARRANTY PROVIDED IN LIEU OF ALL OTHER WARRANTIES AND CUSTOMER S WAIVER O...

Страница 5: ...ed balancing spring 002 LB38 Board for the connection of three 12V 6Ah emergency batteries The following accessories are optional to the G4140ZU G4140IZU automation system 001 G02801 Flashing dome lam...

Страница 6: ...le barrier support 11 G02809 Adhesive reflector strips 12 G02801 Flashing dome lamp 13 G03751 Emergency battery housing support 14 G03753 Attachment flange for elyptical bar 11 CAME CAME CAME CAME VIE...

Страница 7: ...the area selected for the mounting of the base and for the unit itself presents no hazards Provide for suitable omnipolar disconnection device with more than 3 mm between contacts to section power sup...

Страница 8: ...4 Red phosphorescent strips 5 Luminous cord 6 Movement indicating flashing lamp 7 Column for photoelectric cells 8 Photoelectric cells 9 Fixed barrier support 10 Magnetic sensor 11 Photoelectric cell...

Страница 9: ...clamps at the base Prepare a hole to house the fixing base and prepare sheath tubes from the branch pit for the connections Note The number of tubes depends on the type of system and the accessories...

Страница 10: ...rn it counter clockwise 1 1 2 4 3 Should installation on the right be required the direction of the bar s opening must be inverted Proceed in the following manner remove the anchor bolt for springs fr...

Страница 11: ...s conduit a procedure that should be carried out on both sides Insert the shock resistant profile and cut excess length Lastly secure the bar end plug with the screws provided Position the middle plat...

Страница 12: ...k Bare bar luminous cord and rack Bare bar shock resistant profile and mobile barrier support Barebar shock resistantprofile luminouscordandmobilebarriersupport Bare bar rack and mobile barrier suppor...

Страница 13: ...lation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s p a to notify users Release the gearmotor and position the bar vertically and then refasten the...

Страница 14: ...e anchoring bracket release the gearmotor and manually turn the spring to increase or decrease traction until the bar rests at 45 45 4 5 1 2 Tighten the blocking nut and refasten the gearmotor Note ma...

Страница 15: ...tes the slowing down microswitch prior to the bar s total stop 5 8 End stop adjustment Note perform this procedure after finishing the electrical connections Close the door and power up the system act...

Страница 16: ...E cancelli automatici s p a to notify users After bar opening and closing adjustment tighten the locking nuts under the dampers reposition the inspection door and top crown Once you have completed all...

Страница 17: ...must not exceed 40 W overall The control unit is fitted with an amperometric device which constantly regulates the motor s drive coefficient When the bar runs into an obstacle the amperometric sensor...

Страница 18: ...for radio codes automatic closing 12 Adjustment connectors for deceleration speed 13 Connectors for LB38 battery charger 14 Command type selection jumper for button 2 7 15 Transformer 16 Power supply...

Страница 19: ...Excludes automatic closing For motion to resume press the command button or the remote control button If it is not used place the dip 9 on Command button N O contact Bar opening or clo sing button By...

Страница 20: ...btained If not used short circuit contact 2 C1 DIR photocells Safety devices N L L27 L1T E 10 11 1 2 3 5 7 C1 C5 C O M Rallentam Velocit Max Max Med Min Min DIS 27370 A B 6 3 Adjusting movement and de...

Страница 21: ...conds before motion begins 6 ON Obstacle detected When motor is stopped bar closed or after a total stop command it prevents any movement if safety devices such as photocells detect any obstacles 7 ON...

Страница 22: ...to notify users 7 Activating the remote control ON 2 1 3 4 5 6 7 8 9 10 N M PT F FC FA N L L27 L1T E 10 11 1 2 3 5 7 C1 C5 GND TX RX Connect the antenna s RG58 cable to the apposite terminals Antenna...

Страница 23: ...2 1 3 4 5 6 7 8 9 10 N M PT F FC FA N L L27 L1T E 10 11 1 2 3 5 7 C1 C5 GND TX RX ON 2 1 3 4 5 6 7 8 9 10 N M PT F FC FA N L L27 L1T E 10 11 1 2 3 5 7 C1 C5 GND TX RX Radiofrequency board PROG Keep p...

Страница 24: ...chosen Master command card perform all the connections see electrical connections paragraph the installation procedure for the remote control settings and adjustments CAME R MASTER COMMAND CARD ON 2...

Страница 25: ...ntrols and any other command dev ice out the reach of children to prevent operator from being activated by accident In the event of anomalous behaviour stop using the operator immediately Danger of cr...

Страница 26: ...te of job Technician s signature Requester s signature Job performed________________________________________________________________________________________ ___________________________________________...

Страница 27: ...heck power supply and fuses No automatic closure 11 12 13 4 N C safety contacts open 1 2 2 C1 2 C5 The unit does not work if the remote control is used 2 14 16 6 Disable master slave function The unit...

Страница 28: ...s of materials Most of them aluminium plastics iron electrical wires etc may be disposed of in normal garbage collection bins and can be recycled by disposing of in specific recyclable material collec...

Страница 29: ...THIS PAGE LEFT INTENTIONALLY BLANK THIS PAGE LEFT INTENTIONALLY BLANK...

Страница 30: ...THIS PAGE LEFT INTENTIONALLY BLANK THIS PAGE LEFT INTENTIONALLY BLANK...

Страница 31: ...THIS PAGE LEFT INTENTIONALLY BLANK THIS PAGE LEFT INTENTIONALLY BLANK...

Страница 32: ...5 433 3307 Fax 305 396 3331 Manual code 119GV29 ver 2 0 09 2010 CAME cancelli automatici s p a The data and information reported in this installation manual are susceptible to change at any time and w...

Отзывы: