background image

SWING GATE OPENERS

FOR RESIDENTIAL

USER MANUAL

24V DC GEAR MOTOR

Flashing Light

Control box

Push Button

Gate 2

Gate 1

Содержание PL1000

Страница 1: ...SWING GATE OPENERS FOR RESIDENTIAL USER MANUAL 24V DC GEAR MOTOR Flashing Light Control box Push Button Gate 2 Gate 1 ...

Страница 2: ......

Страница 3: ... and Its Installation in Illustration 3 2 Power Connection 3 2 1 Notes for Power Connection 3 3 Installation 3 3 1 Preparation for Motor Installation 3 3 2 Installation of The Gear Motors 3 3 3 PKS 1 Key Selector 3 3 4 PPB 1 Push Button 3 3 5 PF 1 Flashing Light 3 3 6 PH 1 Photocells 3 3 7 PEL 1 Electric Latch and PS 1 Stopper 4 Technical Characteristics 4 1 PW150 4 2 PW200 4 3 PH 1 Photocells 4 4...

Страница 4: ...orks properly before installing the gate automated system and confirm the gates are appropriate for the application Do not let children operate or play with the gate automated system Do not cross the path of the gate automated system when operating Please keep all the control devices and any other pulse generator away from children to avoid the gate automated system being activated accidentally Do...

Страница 5: ...cessories of a gate automation system 2 3 Description of Devices A B C D E PW150 PW200 includes the accessories shown in Figure 2 Please check the accessories the same as the package provided Attention Some accessories of PW150 PW200 are not included due to local regulations or customized order A 2 PW150 PW200 electromechanical gear motors B Mounting brackets C 1 pair of PH 1photocells one TX and ...

Страница 6: ...gure 6 2 3 3 PH 1 Photocells The pair of PH 1 photocells has to be installed on the wall and connected to the control panel The function of the photocells is to detect the obstacles found on the optical axis between the transmitter TX and the receiver RX 2 3 4 PR 1 Radio Transmitter PR 1 radio transmitter is used for the remote control of the gate movement To use the transmitter press and hold the...

Страница 7: ...radio transmitter PKS 1 key selector is supplied with two keys 2 3 7 PPB 1 Push Button The PPB 1 push button is used for opening the gate indoors without the radio transmitter 3 1 Notes of Motors in Operation The PW150 PW200 gate openers are applicable to per leaf of 2 2 5 meters in width and 150 200 kg in weight which can be opened up to 110 degrees primarily for residential use where the perform...

Страница 8: ...200 requires very low voltage that no professionally trained personnel is required in installation however the users are advised to read the installation manual carefully before going for it After getting to know all accessories and their positions suggest starting from cable conduit arrangement to prevent the cables from being broken or damaged 3 2 Power Connection 1 The installation of power sup...

Страница 9: ...rce regulations 3 Make sure there is no serious friction existing in the opening or closing travel of the gate leaves 4 Make sure the gate is at horizontal level that the gate will not move aside at any position 5 Make sure the gate can bear the impact of the motor torque when it is installed on any hole of the bracket which the surface is sufficiently sturdy 6 Make sure the photo sensors are inst...

Страница 10: ...value of B can be calculated from the value of A and the leaves opening angle Ex If A 160mm with the leaves opening angle of 100 degrees then the value of B is approximate 190mm Please make sure B and A are similar or the same in value that the leaves can be operated smoothly also to reduce the burden of the motor 9 If the gate is OPENED OUTWARD please leave at least 70mm between the post brackets...

Страница 11: ... 17 place the rear plate in the correct position on the mounting surface Inspect if the distance is proper as shown in Figure 22 i e the position the front plate of the motor to be installed 7 Place two post brackets on the surface to be installed and mark the drilling points then drill minimum diameter of 8mm holes by four on the mounting surface to be installed and fasten up the brackets with sc...

Страница 12: ...screw 15 Use appropriate release key to release the gear motor 16 Try to push the released gate and make sure the motor can be manually moved easily 17 Make sure the motor front plate can be fastened on the gate to be installed permanently 18 Use the appropriate release key to fasten the gear motor again 19 Loosen the plastic nut under the power cable of the motor end and penetrate the power cable...

Страница 13: ...the three holes at the bottom and mark the points by the holes as reference 6 Drill the holes in the wall and fix the bottom to the wall by three screws See Figure 3 3 3 5 7 Connect the electric wires to the terminals as shown in Figure 3 3 3 6 and it s not required to distinguish any polarity The terminals can be removed for connecting the wires easily 8 Turn the key and insert the shell on the b...

Страница 14: ...ght of about 100cm so that it could be used by most people 2 Remove the round cover A by prizing it out with a screwdriver See Figure 3 3 4 1 3 Unscrew the two screws beside the button 4 Separate the upper shell with the bottom See Figure 3 3 4 2 5 Breach the three holes at the bottom and mark the points by the holes as reference 6 Drill the holes in the wall and fix the bottom to the wall by thre...

Страница 15: ...ry See Figure 3 3 5 5 6 Tighten the four screws back on the light base Figure 3 3 5 6 7 Replacing the bulb set See Figure 3 3 5 7 7 1 Unscrew the flashing light wires from the PCB terminals and make sure the power of the light is off 7 2 Release the three screws A B C of the flashing light cover 7 3 Separate the flashing light cover and replace the bulb set with a new one 7 4 Tighten the three scr...

Страница 16: ...ttach the stopper to the ground with screws and washers See Figure 3 3 7 3 3 Wiring connection TX Connect the 1 and 2 terminals on the transmitter with the terminals GND and 24V on the PL600 1000 PCB RX Connect the 1 2 and NC terminals on the receiver with the terminals GND 24V and PH1 on the PCB600 1000 PCB See Figure 3 3 6 4 Figure 3 3 6 5 Figure 3 3 6 4 Figure 3 3 6 5 CA CC NA Normal Open NC No...

Страница 17: ... 7 7 2 Weld the back plate of the electric latch to the surface on the master gate See Figure 3 3 7 8 Please avoid melting the wires by the heat of the fixed plate Figure3 3 7 4 Unscrew the screws Figure3 3 7 7 Change the spring and screw it in the different place Figure3 3 7 8 For the gate opened inward Figure3 3 7 9 For the gate opened Outward Installation Figure3 3 7 5 Take the casing off Figur...

Страница 18: ...Worm gear 1500N 360mm 24Vdc 4 2A for maximum 10 seconds 150 kg per leaf 2 meters 20 20 50 674mm 98mm 170mm 3 1kg 24Vdc motor with mechanical release Worm gear 2000N 400mm 24Vdc 4 2A for maximum 10 seconds 200 kg per leaf 2 5 meters 20 20 50 799mm 98mm 170mm 3 6kg PW150 PW200 4 3 PH 1 Photocells Detection type Operating distance Response time Input voltage Operating Temperature Protection class Dim...

Страница 19: ...e Operating Current Dimension For locking the gate 24Vdc 20 50 5A 61mm 55mm 120mm 4 6 PF 1 Flashing Light Application Lamp Operating Temperature Installation Dimension For warning purpose during leaves movement 24Vdc Halogens bulb 20 50 horizontally or vertically installed 205mm 80mm 75mm 1095 Budapest Mester u 34 Tel 218 5542 215 9771 215 7550 216 7017 216 7018 Fax 218 5542 Mobil 30 940 1970 20 9...

Отзывы: