Tamarisk
®
640
Software ICD
29
6
checksum
Frame check sequence.
Table 40 – Digital Video Source IDs
Source ID
Description
0
Test Pattern Generator
6
14 bit data with no invert/revert, no gray
or freeze frame during auto-calibrations
7
14 bit data with 1 frame of latency with
invert/revert, gray or freeze frame
support during auto-calibrations
8
Output of AGC Module.
9
Output of Symbology Module.
All other values reserved.
Response Format:
Table 41 – Digital Video Source Select Response Format
Byte
Value
Description
1
0x01
Start of message.
2
0x02
ACK Response
3
0x02
Parameters length.
4, 5
0x00D7
Digital Video Source Select Command ID.
6
checksum
Frame check sequence.
3.1.8 Baud Rate Set – 0xF1
Description
: Set the baud rate for the RS232 serial port. The system must be using RS-
232 serial for this command to have an effect.
NOTE
Note: the baud rate for the USB port is fixed at 921600.
Note: there is no acknowledge of this command, any subsequent commands
must be at the new baud rate.
The factory default setting is 57600 baud. There is a non-volatile parameter to permanently
change this. If a different baud rate is desired, there must be an initial command to change
the baud rate at 57600 baud. Or the non-volatile-parameter (#34) must be set to the desired
baud rate.
Note: the baud rate for the USB port is fixed at 921600.