Tamarisk
®
640
Software ICD
63
3.
If flash programming fails, this command results in an ERR response containing an
informative string.
WARNING
This command will reset the camera back to factory defaults, any customer
non-volatile parameter changes will be lost (this will not effect customer flash
sector or customer dead cell map).
Command Format:
Table 113 – Non-Volatile Parameters Default Set Command Format
Byte
Value
Description
1
0x01
Start of message.
2
0xB3
Non-Volatile Parameters Set Default Command ID.
3
0x00
Parameters length.
4
checksum
Frame check sequence.
Response Format:
Table 114 – Non-Volatile Parameters Default Set Response Format
Byte
Value
Description
1
0x01
Start of message.
2
0x02
ACK Response
3
0x02
Parameters length.
4, 5
0x00B3
Non-Volatile Parameters Set Default Command ID.
6
checksum
Frame check sequence.
3.5.2 Non-Volatile Parameters Get – 0xB5
Description
: Displays the value of the selected Non-Volatile Parameter
Command Format:
Table 115 – Non-Volatile Parameters Get Command Format
Byte
Value
Description
1
0x01
Start of message.
2
0xB5
Non-volatile parameters get command ID.
3
0x02
Parameters length.
4, 5
Unsigned integer
Non-volatile parameter ID.
6
checksum
Frame check sequence.