Tamarisk
®
640
Software ICD
54
Command Format:
Table 105 – Zoom Magnification Set Command Format
Byte
Value
Description
1
0x01
Start of message.
2
0xA4
Zoom Magnification Set Command ID.
3
0x02
Parameters length.
4, 5
Unsigned integer.
See table below.
Zoom magnification ID value.
6
checksum
Frame check sequence.
Table 106 – Zoom Magnification ID Values
Zoom Magnification ID
Zoom
0
1.00
7
2.75
1
1.25
8
3.00
2
1.50
9
3.25
3
1.75
10
3.50
4
2.00
11
3.75
5
2.25
12
4.00
6
2.50
-
-
Response Format:
Table 107 – Zoom Magnification Set Response Format
Byte
Value
Description
1
0x01
Start of message.
2
0x02
ACK Response
3
0x02
Parameters length.
4, 5
0x00A4
Zoom Magnification Set Command ID.
6
checksum
Frame check sequence.
3.4.2 Zoom Pan Set – 0xA5
Description:
Selects the origin from within the un-zoomed, original image for the zoomed
image subset. The origin is the zero-based offset of the center of the zoomed image. The
offset [0,0] is the center of the un-zoomed image.