Tamarisk
®
640
Software ICD
58
ID
Name
Type
Values
Default
Value
Notes
18
Genlock
Master Enable
Boolean
0 = slave mode
non-zero = master
mode
0
This value has no effect when
GENLOCK is disabled.
19
Genlock Delay
Unsigned
integer
0 to 255 clocks.
0
The number of system clocks
to delay the generated
Genlock signal when enabled
and in master mode. “0” is no
delay. This value has no effect
when GENLOCK is disabled.
34
Serial Port
Baudrate
Unsigned
integer
See Serial Baudrate
command in Section
3.1.9 for complete
listing of selectable
baudrates.
2
Default power-on serial
communication baudrate.
35
AutoCal
Activity
Control
Boolean
0: Disable
1: Enable
1
Controls whether AutoCal
activities, including range
change are allowed after
power-up.
Note: Power-up 1-Pt is always
performed to provide best
initial image.
36
AGC Gain
Limit Noise
Reduction
Mode
Unsigned
fixed-point
integer
0x0010: Enable
0x0FFF: Disable
0x0010
Controls the AGC Noise
Reduction Gain Factor. Set to
0x0FFF to disable noise
reduction mode.
38
AGC Black
Hot Enable at
Power Up
Boolean
0: Disable
1: Enable
0
Value is applied only at the
time of power up.
39
AGC Auto
Mode Gain
Bias at Power
Up
Unsigned
integer
0-4096
2047
Value is applied only at the
time of power up.
40
AGC Auto
Mode Level
Bias at Power
Up
Unsigned
integer
0-4096
2047
Value is applied only at the
time of power up.
41
AGC Manual
Mode Gain at
Power Up
Unsigned
integer
0-4096
3840
Value is applied only at the
time of power up.
42
AGC Manual
Mode Level at
Power Up
Unsigned
integer
0-4096
2047
Value is applied only at the
time of power up.
43
AGC Mode at
Power Up
Unsigned
integer
0: Freeze/Off
1: Auto Mode
2: Manual Mode
1
Value is applied only at the
time of power up.