Table 24 – Data Transfer Upload Packet Response ID
ID
Description
CU Response
3‡
Packet out of order.
Restart transmission from the packet number
included in the message.
4
Upload complete. Flash operations
underway.
CU should cease transmission of packets
until follow-up message is received.
5
Transfer CRC error.
CU should cease data transfer operations
6
Data length error.
CU should cease data transfer operations
8
Flash sector programming underway.
CU should stop transmitting packets and wait
for follow-up messages.
9
Flash sector programming complete.
CU should resume transmission of packets.
10
Transfer complete.
CU should cease data transfer operations.
‡The TIM shall send this response to the CU any time it detects a gap in the packet