Tamarisk
®
640
Software ICD
61
ID
Name
Type
Values
Default
Value
Notes
67
Zoom
Magnification
Power on
Value
Unsigned
integer
0 = 1.00X
1 = 1.25X
2 = 1.50X
3 = 1.75X
4 = 2.00X
5 = 2.25X
6 = 2.50X
7 = 2.75X
8 = 3.00X
9 = 3.25X
10 = 3.50X
11 = 3.75X
12 = 4.00X
0
68
Zoom
Horizontal
Offset Power
On Value
Signed
Integer
Horizontal offset from
the center.
- Negative values center
the zoom to the left of
FPA center.
- Positive values center
the zoom to the right of
FPA center.
- Range depends on
power-on zoom
magnification.
- Values out of range
will be clipped at
maximum.
0
69
Zoom Vertical
Offset Power
On Value
Signed
Integer
Vertical offset from the
center.
- Negative values center
the zoom above the
FPA center.
- Positive values center
the zoom below the
FPA center.
- Range depends on
power-on zoom
magnification.
- Values out of range
will be clipped at
maximum.
0
71
ICE Power-On
Slope Limit
Unsigned
Integer
1 to 63, where:
1 = 0.25
2 = 0.50
…
8 = 2.00
…
63 = 15.75
8
Camera RTL Rel version
01.00.3532 or newer is
required together with
compatible CPU(Rel) version.
Deprecated, please use parameter 79
for ICE strength adjustments
72
Crosshairs
Enable
Boolean
0 = disabled
non-zero = enabled
0