Tamarisk
®
640
Software ICD
57
ID
Name
Type
Values
Default
Value
Notes
7
Video Output
Mux Select
Unsigned
integer
0 = Output of
Uploaded Test Pattern
6 = 14 bit data with no
invert/revert, no gray
or freeze frame during
auto-calibrations
7 = 14 bit data with 1
frame of latency with
invert/revert, gray or
freeze frame support
during auto-
calibrations
8 = AGC
9 = Symbology
All other values
reserved.
9
The output of the selected
processing block will be output
to all video output ports
(RS170, parallel digital video,
and Camera Link).
8
AGC Gain
Limit
Unsigned
integer
0 to 4095
0
This has no effect unless
parameter 36 is maximum
value 0x0FFF
9
AGC Gain
Flatten Offset
Unsigned
integer
0 to 65535
3
11
AGC
Upper/Lower
Bounds
Percent
Unsigned
integer
0 to 100 (%).
1
14
Automatic
Field
Calibration
Interval
Unsigned
integer
1 to 65535 minutes
5
Interval between automatic
field calibrations. Setting this
value to 0 will disable time-
based automatic calibrations
(not all calibrations will be
disabled).
This value must be greater
than the minimum Autocal
interval.
16
Frame Rate
Unsigned
integer
1 = 30 hz
2 = 24 hz
3 = 18 hz
4 = 15 hz
5 = 12 hz
6 = 9 hz
7 = 6 hz
8 = 3 hz
All other values
reserved.
1 or 6
A 30 Hz camera can be set to
any supported lower frame
rate. A 9 Hz camera can only
be set to 9 Hz.
17
Genlock
Enable
Boolean
0 = disabled
non-zero = enabled
0