Tamarisk
®
640
Software ICD
19
2.7.1 Data Transfer Upload Setup – 0x74
This message is used as both a command to the TIM and a response to the CU.
Description:
Sets up a transfer from the connected unit to the TIM.
Command Format:
Table 19 – Data Transfer Upload Setup Command Format
Byte
Value
Description
1
0x01
Start of message.
2
0x74
Data Transfer Upload Setup Command ID.
3
0x12
Parameters length.
4, 5
Unsigned integer
0x00, 0x00
6, 7
Unsigned integer
0x00, 0x01
8, 9
Unsigned integer
Software: 0x00, 0x0C FPGA:0x00, 0x0E
9, 10
Unsigned integer
0x00, 0x00
10, 11
Unsigned integer
0x00, 0x00
12, 13
Unsigned integer
0x00, 0x00
14, 17
Unsigned integer
Total size of transfer.
18, 19
Unsigned integer
CRC of entire transfer.
6
checksum
Frame check sequence.
Response Format:
Table 20 – Data Transfer Upload Setup Response Format
Byte
Value
Description
1
0x01
Start of message.
2
0x74
Data Transfer Upload Setup Command ID.
3
0x06
Parameters length.
4, 5
0x0000
Always 0.
6, 7
0x0000
Always 0.
7, 8
Unsigned Integer
Response ID. See table below.
9
checksum
Frame check sequence.
Table 21 – Data Transfer Upload Setup Response ID
Response ID
Description
1
Success, Setup accepted. Upload can proceed.
3
Error in Device ID, Region ID, or Range ID. Setup failed.