Tamarisk
®
320
Software ICD
34
4, 5
0x00AC
Automatic calibration toggle command ID.
6
checksum
Frame check sequence.
3.2.4 Automatic Calibration Period Set – 0x12
Description
: This command shall set the period between automatic calibrations (autocal
period). This command does not store the autocal period in non-volatile storage to be
preserved across power cycles. A setting of zero (0) is will prevent only periodic automatic
calibrations, not all automatic calibrations.
The default for time based automatic calibrations is five minutes.
Command Format:
Table 56 – Automatic Calibration Period Set Command Format
Byte
Value
Description
1
0x01
Start of message.
2
0x12
Automatic calibration period set command ID.
3
0x02
Parameters length.
4, 5
Unsigned integer
Automatic calibration period in minutes.
6
checksum
Frame check sequence.
Response Format:
Table 57 – Automatic Calibration Period Set Response Format
Byte
Value
Description
1
0x01
Start of message.
2
0x02
ACK Response
3
0x02
Parameters length.
4, 5
0x0012
Automatic calibration period set command ID.
6
checksum
Frame check sequence.
3.2.5 Automatic Calibration Period Get – 0x13
Description
: This command shall retrieve the period between automatic calibrations
(autocal period).