Tamarisk
®
320
Software ICD
57
ID
Name
Type
Values
Default
Value
Notes
7
Video Output
Mux Select
Unsigned
integer
4 = 14 bit data, output
of zoom module
5 = AGC
All other values
reserved.
5
The output of the selected
processing block will be output
to all video output ports
(RS170, parallel digital video,
and Camera Link).
These settings are for camera
RTL Rel versions 01.00.0080
or prior. See previous row for
newer camera settings.
8
AGC Gain
Limit
Unsigned
integer
0 to 4095
0
This has no effect unless
parameter 36 is maximum
value 0x0FFF
9
AGC Gain
Flatten Offset
Unsigned
integer
0 to 65535
3
11
AGC
Upper/Lower
Bounds
Percent
Unsigned
integer
0 to 100 (%).
1
14
Automatic
Field
Calibration
Interval
Unsigned
integer
1 to 65535 minutes
5
Interval between automatic
field calibrations. Setting this
value to 0 will disable time-
based automatic calibrations
(not all calibrations will be
disabled).
This value must be greater
than the minimum Autocal
interval.
16
Frame Rate
Unsigned
integer
0 = 60 hz
1 = 30 hz
2 = 24 hz
3 = 18 hz
4 = 15 hz
5 = 12 hz
6 = 9 hz
7 = 6 hz
8 = 3 hz
All other values
reserved.
0 or 6
A60 Hz camera can be set to
any supported lower frame
rate. A 9 Hz camera can only
be set to 9 Hz.
17
Genlock
Enable
Boolean
0 = disabled
non-zero = enabled
0
18
Genlock
Master Enable
Boolean
0 = slave mode
non-zero = master
mode
0
This value has no effect when
GENLOCK is disabled.