Tamarisk
®
320
Software ICD
23
Byte
Value
Description
2
0x02
ACK Response
3
0x02
Parameters length.
4, 5
0x0007
System Version Get Command ID.
6
checksum
Frame check sequence.
3.1.2 Customer Non-Volatile Read Command – 0xCA
Camera RTL Rel version 01.00.0080 or newer is required together with compatible
CPU(Rel) version.
Description
: Allows a customer to read up to 252 ASCII characters. This information is
read out of non-volatile memory and can be read back with the Customer Non-Volatile
Read Command.
Command Format:
Table 29 – Customer Non-Volatile Read Command Format
Byte
Value
Description
1
0x01
Start of message.
2
0xCA
Customer Non Volatile Read Command ID.
3
0x00
Parameters length.
4
checksum
Frame check sequence.
Response Format:
Table 30 – Customer Non-Volatile Read Response Format
Byte
Value
Description
1
0x01
Start of message.
2
0x02
ACK Response
3
NN
Parameters length, where 10<N<252..
4 to
(N+3)
varies
Non-volatile memory contents.
(N+4)
checksum
Frame check sequence.
3.1.3 Customer Non-Volatile Write Command – 0xCB
Camera RTL Rel version 01.00.0080 or newer is required together with compatible
CPU(Rel) version.