Tamarisk
®
320
Software ICD
39
1 enables ICD mode.
6
checksum
Frame check sequence.
Response Format:
Table 69 – ICE Mode Response Format
Byte
Value
Description
1
0x01
Start of message.
2
0x02
ACK Response
3
0x02
Parameters length.
4, 5
0x0023
ICE Enable Command ID.
6
checksum
Frame check sequence.
3.3.3 ICE Mode Strength Command – 0x1E
Camera RTL Rel version 01.00.4471 or newer is required.
Description
: Sets ICE Strength. (ICE Mode must be enabled before this command will
have any effect). This command, enables the user to select an ICE strength from 0-7 in 1
unit increments. The lowest setting is 0; the highest setting is 7. Recommend using lower
values when looking at lower contrast scenes and higher values when looking at dynamic
scenes.
Command Format:
Table 70 – ICE Mode Strength Command Format
2
0x1E
ICE Mode Strength Command ID.
3
0x02
Parameters length.
4, 5
0x0000…0x0007
ICE Strength value.
6
checksum
Frame check sequence.
Response Format:
Table 71 – ICE Mode Strength Response Format
4, 5
0x001E
ICE Mode Strength Command ID.
6
checksum
Frame check sequence.
3.3.4 ICE Mode High-Frequency Threshold Command – 0x1F(
Deprecated, please use
command 0x1E for ICE adjustments)
Camera RTL Rel version 01.00.4189 or newer is required together with compatible
CPU(Rel) version.