Tamarisk
®
320
Software ICD
21
3
O
P E R A T I O N A L
C
O M M A N D S
The operational commands are those used by the TIM during normal operations. These commands
may also be used during factory calibration and testing.
3.1 SYSTEM COMMANDS
3.1.1 System Version Get – 0x07
Description
: This command returns the system version. The response to the command is
a series of TXT messages followed by an ACK message.
Figure 3– System Version Get Diagram
Command Format:
Table 25 – System Version Get Command Format
Byte
Value
Description
1
0x01
Start of message.
2
0x07
System Version Get Command ID.
3
0x00
Parameters length.
4
checksum
Frame check sequence.
Response Format:
The TIM will respond with one or more TXT messages. Each TXT message shall contain a
null-terminated string of less than 40 characters. The number of messages and their
contents are system-specific... As an example, below are the version strings for
Tamarisk
®
320
.
1.
System Name – “System: Tamarisk-320”
2.
CPU Software Version String – This is the version number of the current software
release. Example format: “CPU Version: X1.P1.01.01.04”
3.
Company Name – “DRS Technologies”
CU
TIM
0x07 (0)
0x02 (2)
0x00 (varies)
•••
0x00 (varies)
TXT
TXT
System Version Get
TXT
ACK