Tamarisk
®
320
Software ICD
42
2
0x02
ACK Response
3
0x02
Parameters length.
4, 5
0x0028
AGC Mode Command
6
checksum
Frame check sequence.
3.3.7 AGC White-Hot Polarity Set – 0x29
Description
: Commands the system to display hotter objects in the image as lighter
(whiter) and cooler objects as darker. This is the default.
Command Format:
Table 79 – AGC White Hot Polarity Set Command Format
Byte
Value
Description
1
0x01
Start of message.
2
0x29
AGC White-Hot Polarity Set Command ID.
3
0x00
Parameters length.
4
checksum
Frame check sequence.
Response Format:
Table 80 – AGC White Hot Polarity Set Response Format
Byte
Value
Description
1
0x01
Start of message.
2
0x02
ACK Response
3
0x02
Parameters length.
4, 5
0x0029
AGC White-Hot Polarity Set Command ID.
6
checksum
Frame check sequence.
3.3.8 AGC Manual Gain Set – 0x32
Description
: Sets gain value used by AGC when configured to Manual Mode.
NOTE
This command has no effect if ICE is enabled.