Tamarisk
®
320
Software ICD
20
Response Format:
Table 23 – Data Transfer Upload Packet Response Format
Byte
Value
Description
1
0x01
Start of message.
2
0x72
Data Transfer Upload Setup Command ID.
3
0x06
Parameters length.
4, 5
unsigned integer
Response ID. See table below.
6, 7
unsigned integer
Packet number. First packet is 0.
8
checksum
Frame check sequence.
Table 24 – Data Transfer Upload Packet Response ID
ID
Description
CU Response
3‡
Packet out of order.
Restart transmission from the packet number
included in the message.
4
Upload complete. Flash operations
underway.
CU should cease transmission of packets
until follow-up message is received.
5
Transfer CRC error.
CU should cease data transfer operations
6
Data length error.
CU should cease data transfer operations
8
Flash sector programming underway.
CU should stop transmitting packets and wait
for follow-up messages.
9
Flash sector programming complete.
CU should resume transmission of packets.
10
Transfer complete.
CU should cease data transfer operations.
‡The TIM shall send this response to the CU any time it detects a gap in the packet
number sequence. The packet number in the response shall be the packet number of the
last packet received in the proper sequence.