August 2009
3 -
Cafitesse 100 Next Generation
Errors
3.1 Errors water system
No. Description
Over-
rules
Set condition
Reset condition
Remarks
Cause
Remedy
Priority
10
Overboil safety
has tripped
21
Software detects
the over boil has
tripped.
Temp 80 °C
(178 °F)
Automatically
when software
detects that sa-
fety is manually
reset
Overboil sensor defective
or
heating is ON for too long:
Temperature sensor defective
Heating or safety relays defec-
tive
or
there is a boiler overflow:
High level sensor is defective.
Inlet valve does not close.
1.
2.
3.
4.
5.
Check the overboil sensor
or
Check the temperature sensor
and wiring.
Check and the heating or safe-
ty relays and wiring.
or
Check the high level sensor
and wiring.
Check, if the inlet valve is not
leaking.
Check the MCB and wiring.
Replace components if neces-
sary.
1.
2.
3.
4.
5.
6.
120
11
Boiler water level
is too low
Low level sensor
= dry
Reset by re-
powering the
dispenser
Water supply tap not open or
blocked
Water pressure is too low
Inlet valve is defective
Overflow hose is blocked
Low level sensor defective
Wiring incorrect or
connections defective
MCB defective
1.
2.
3.
4.
5.
6.
7.
Open or clean tap
Check water pressure (see
chapter 2)
Check / replace inlet valve
Check and clean/replace over-
flow hose
Check / replace low level
sensor
Check wiring and replace con-
nections
Replace MCB (see chapter 5K)
1.
2.
3.
4.
5.
6.
7.
120
1)
Errors are reset by pressing the Lock/clear button in cleaner-, operator-, service- or development mode is shown
2)
Not valid for Cafitesse 100 NG
3)
Valid for Cafitesse 120 NG only
Содержание Cafitesse 110
Страница 1: ...DRAFT Version August 2009 D R A F T Service Manual Cafitesse 110 Cafitesse 120 Next Generation ...
Страница 2: ... 2009 Douwe Egberts Coffee Systems International DRAFT Version August 2009 D R A F T ...
Страница 22: ...D R A F T Cafitesse 100 Next Generation Installation Putting into operation 2 20 August 2009 ...
Страница 54: ...Cafitesse 100 Next Generation Programming 4 20 August 2009 ...
Страница 58: ...D R A F T Cafitesse 100 Next Generation Functions Overview of assemblies 5 August 2009 ...
Страница 71: ...Cafitesse 100 Next Generation Functions water system August 2009 5A 13 ...
Страница 82: ...Cafitesse 100 Next Generation Functions dosing system 5C 10 August 2009 ...
Страница 83: ...Cafitesse 100 Next Generation Functions housing August 2009 5G 1 G Housing G 1 Adjustments Not available here ...
Страница 93: ......