Cafitesse 100 Next Generation
Functions - water system
August 2009
5A-5
8
10
9
Extract the 2 bolts (6) from the cavity on each
side of the inside wall and place it in the adjacent
hole to support the cooling compartment (fig. 4).
Disassembly of the outlet valves
Unplug the cable harness (7) of the respective
outlet valve at the intermediate connection (fig.
5).
Remove the convection hose (8) beneath the
respective outlet valve (fig. 6).
Pull off the breather hose (9) from the boiler lid
(fig. 6).
Pull off the outlet hoses (10) of the respective
outlet valve (fig. 6).
Turn the respective valve (11) counterclockwise
and downwards and take it out of the bracket
(fig. 7).
•
•
•
•
•
•
Fig. 4
Fig. 5
Fig. 7
11
Fig. 6
7
6