Booth ventilation off
Possible cause
: missing signal from booth external ventilation system
control.
Fault elimination:
if the condition is inconsistent, check the external wiring
connection. Tap on the reset alarm button on the panel.
Emergency push
button triggered
Possible cause
: the emergency push button on the control panel is pressed.
Fault elimination:
release the emergency button and tap on the reset alarm
button on the panel. if the condition is inconsistent, check the internal wiring
connection
Error in output
regulation table
Possible cause:
while working with closed loop flow control in automatic
mode, the output cannot be calculated for the request flow from the recipe
regulation table data
.
Fault elimination:
check if the regulation data table for the recipe in use are
correct: growing values left to right, covering the requested flow set point.
Error saving the
consumption of flash
Possible Cause:
There was an error during the daily process of writing data
consumption on the flash memory accessible via FTP.
Fault elimination
: check the label name (couple of letters) to the saved data
files (see parameter section 4 page settings).
Check that the flash is present consumption folder,
path F: \ Consumption \ where the file is saved.
Leave blank the file name field to disable the daily save function if not used