99
LEADING IN PRODUCTION EFFICIENCY
Operating Manual
© Dürr Systems AG
ED3K_Operating_Manual_Rev02LD_03Lug2020_EN. docx
Rev.02 – 03.07.2020
8.8.2
Input from external control interface
INPUT FROM
EXTERNAL
CONTROLLER
0.0
iAckTelCount
INT
Acknowledge telegram counter => Ext
2.0
iDateYear
INT
Date year => Ext
4.0
bDateMonth
BYTE
Date month => Ext
5.0
bDateDay
BYTE
Date day => Ext
6.0
bTimeHours
BYTE
Time hours => Ext
7.0
bTimeMinutes
BYTE
Time minutes => Ext
8.0
bTimeSeconds
BYTE
Time seconds => Ext
9.0
iSpareO_9
BYTE
10.0 iSpareO_10
INT
12.0 iSpareO_12
INT
14.0 iSpareO_14
INT
16.0 iSpareO_16
INT
18.0 iSpareO_18
INT
20.0 mrelStOn
BOOL Release switch on EcoDose3K from main station
20.1 mSpare
BOOL
20.2 mTimeSync
BOOL Set date and time from external control
20.3 mSpareO_20_3
BOOL
20.4 mSpareO_20_4
BOOL
20.5 mSpareO_20_5
BOOL
20.6 mSpareO_20_6
BOOL
20.7 mSpareO_20_7
BOOL
21.0 mSpareO_21_0
BOOL
21.1 mSpareO_21_1
BOOL
21.2 mSpareO_21_2
BOOL
21.3 mSpareO_21_3
BOOL
21.4 mSpareO_21_4
BOOL
21.5 mSpareO_21_5
BOOL
21.6 mSpareO_21_6
BOOL
21.7 mSpareO_21_7
BOOL
22.0 iNoNewRecipe
INT
New recipe number
24.0 iSpareO_24
INT
26.0 iG1_AtomizPressure
INT
Atomizing air pressure gun 1 , 0-6000 [mbar]
28.0 iG2_AtomizPressure
INT
Atomizing air pressure gun 2 , 0-6000 [mbar]
30.0 iG1_ColorPressure
INT
Color pressure regulator gun 1 0-6000 [mbar]
32.0 iG2_ColorPressure
INT
Color pressure regulator gun 2 0-6000 [mbar]
34.0 iG1_ColorFlow
INT
Set point color flow [ml/min]
36.0 iSpareO_36
INT
38.0 iSpareO_38
INT
40.0 iSpareO_40
INT
42.0 iSpareO_42
INT
44.0 iSpareO_44
INT
46.0 iSpareO_46
INT
48.0 iSpareO_48
INT
50.0 iSpareO_50
INT