The window is divided in three sections.
In the first there is the selection of the recipe on which you want to perform the calibration.
In the second section there are the available commands:
-
to fill just the house portion involved in the calibration with one product, can be color or
component B or C; this is particularly useful to predispose the machine for the calibration
measurement, when measuring the product weight.
-
to clean with solvent, while repeating the test for different recipes.
Set the correct quantity values in the displays.
Each command has its own start button, and can be arrested with the stop button.
The third section, Test, contains three displays:
Pulses for liter
if this field is not already filled in, go to the system page and press the
button
to open the calibration table. Key in the theoretical value of
the flowmeter installed in your machine, or copy it from another recipe.
Required quantity.
Measured quantity.
In the second display “Required quantity” you must enter the amount of the product on which you
want to perform the calibration, then press
to start the cycle program. The volume of
product sprayed must be collected into a measuring cup.
Once the calibration cycle program is ended without error, a confirmation key is shown at the bottom
of the calibration popup window. In the third display “Measured quantity” you must enter the actual
amount of product collected in the measuring cup.
Press the “Confirmation key” (you must be logged in with user level 3), the actual calibration value
is recalculated, and automatically saved in the calibration table.