49
ED250
01-2018
DL4614-080
dormakaba ED250 IG Service Manual
Chapter 20
#
Parameter and
default
Description / Selections
36
Power assist
kraft (force)
0
Force adjustment for
power assist.
0 ... 10
21
Keep closed
force
0
Force activated after
latching action
0 ... 9
50
Manual
release
On
Off; function deactivated. Manual
release button required to
deactivate hold open function.
On; function activated. Moving
door manually in closing direction
from hold open position
deactivates hold open function.
48
Input enable
operator
*
Normal
*
NC contact, operator
deactivated when
contact is open
Inverse
NO contact, operator
deactivated when
contact is closed
#
Parameter and
default
Description / Selections
°/s
°/s
5
Speed open
25
ED250
8 ... 60
27 max.
L.E. mode
6
Speed close
25
ED250
2 ... 60
27 max.
L.E. mode
17
Limit force
open
60
Static force in
opening direction
(wind load control)
(20 ... 150)
N
18
Limit force
close
60
Static force in closing
direction (wind load
control)
(20 ... 150)
N
7
Hold-open
time
5
Hold-open time
automatic mode
(0 ... 180) s
8
Nurse bed
function
10
Hold-open time nurse
bed function
(0 ... 180) s
#
Parameter and
default
Description / Selections
5
Offenhaltez
man.
1
Hold-open time
manual mode
(0 ... 30 s
10
Wall
blanking
80
Angle when system
ignores safety sensor
on hinge side
(60 ... 99)°
19
Latching
action
0
Motor-driven latching
action, automatic
mode
(0 ... 9)
20
Latching
angle
3
Opening angle,
motor-driven latching
angle activated.
(2 ... 10)°
46
Back check
angle
10
Back check angle for
manual opening
cycles.
(5 ... 40)°
51
Coord. offset
angle
30
Starting angle for
second door of two
door system.
(0 ... 30)°
#
Parameter and
default
Description / Selections
49
Input
Night-bank
Normal
*
NO contact; night-
bank function
triggered while contact
closed.
Inverse
NC contact; Night-
bank function
triggered while contact
open.
47
Door depth
35
0 ... 99
mm
0 ... 7/8"
52
Hinge
clearance
3
-5 ... +5
mm
-3/16 ...
+3/16"
I04 Out 1
I04 Out 1
I04 Out 1
I04 Out 1
20.3 Dorma Handheld; driving parameters
20.2.1 Configuration parameters
(continued)
20.3.1 Driving parameters