36
ED250
01-2018
DL4614-080
dormakaba ED250 IG Service Manual
Chapter 17
Parameter
Value
range
Units
Factory
setting Description
Factory setting level
32
1 - 2
1
1
Parameter
SL
is used to determine what data will be reset during factory setting
process.
Standard factory settings
• Program switches OFF.
• Door closed.
• Press 4 button keypad down button
for > 8 s.
1. All parameters reset to factory settings.
2. Procedure completed when "8" on 2 digit displays blinks twice.
3. Installed upgrade cards remain valid and do not require reinstallation.
4. Learning cycle required.
2
Extended factory settings
• Program switches OFF.
• Door closed.
• Press 4 button keypad down button
for > 8 s.
1. All parameters reset to factory settings.
2. Procedure completed when "8" on 2 digit displays blinks twice.
3. Installed upgrade cards deleted from operator memory.
4. Parameter
SL
automatically reset to 1.
5. Control unit and upgrade cards can be used independently (delivery status).
6. Learning cycle required..
Opening angle
1. Door opening angle set during learning cycle is displayed.
2. Opening angle can only be changed during learning cycle.
3. Due to installation and parameter tolerances, display value may not match actual door
position.
33
0 - 110
°
Door closer mode
34
0 - 1
1
0
1. Automatic mode. This mode is applicable whenever door is mainly opened
automatically and where motion detectors are installed.
2. Mode is optimized for high frequency use.
3. Full energy upgrade card provides for higher door opening and closing speeds.
4. In case door is blocked during a closing cycle, operator reverses automatically.
5. Driving phase is optimized to provide reliable closing cycles.
6. Keep closed force (wind load control) parameter
FH
and Push & Go function
parameter
PG
are only available in automatic mode.
1
1. Manual mode. This mode is applicable whenever door is mainly used manually
and only rarely automatically.
2. In case door is blocked during a closing cycle, door will stop at its current position.
3. Driving phase optimized for manual opening cycles.
4. Power assist function parameter
hf
is only available in manual mode.
Power assist activation angle (v1.7)
1. Setting of door activation angle for Power assist function (
hF
).
2. Higher settings of
hA
result in better spring force compensation for easier manual
opening.
3. Power assist function is more sensitive the smaller the activation angle.
35
1 - 5
°
3
17.3.1 Driving parameters detail
(Continued)