3.
Remove drain plug. Allow all transmission
fluid to drain into a receptacle. Properly
dispose of drained fluid. Clean drain plug.
4.
Install drain plug in transmission.
5.
Remove inlet strainer. Use a
nonflammable, non-toxic solvent to clean
strainer.
6.
Inspect gasket on inlet strainer. Replace
gasket if it is damaged. Install inlet strainer.
7.
Remove breather filter. Clean breather
filter and install it.
8.
Rotate filter counterclockwise to remove it.
9.
Clean filter head.
10.
Grease filter gasket and gasket mating
surface on filter head.
11.
Thread filter onto filter head. Tighten filter
1/2 turn after filter gasket contacts filter
head. Filter should be torqued to 1.6 to 2.1
kg m (11.5 to 15 ft lb).
12.
Fill transmission with fluid through fluid
supply pipe. Add fluid until fluid level
reaches low mark on dipstick.
13.
Start engine. Idle engine for two minutes.
14.
With engine idling, check transmission
fluid level. Add fluid until level reaches high
mark on dipstick.
15.
Idle engine until transmission fluid
temperature reaches 82 – 93°C (180 –
200°F). Check fluid level with engine idling.
Level must reach high mark on dipstick.
16.
Check filter for leaks while engine is
running.
Figure 71
Figure 72
Figure 73