4-28 Inspection, Maintenance and Adjustment
022-00029AE Operation and Maintenance Manual
DRAIN WATER FROM HYDRAULIC OIL TANK
1.
Position machine on firm, level ground.
Lower boom and position bucket on
ground. Turn “Off engine.
2.
Position a container under hydraulic
reservoir drain plug. Open reservoir
breather cap (See Figure 10 on page 4-
10). Loosen drain cock from bottom of
reservoir (Figure 49). Allow all water and
sediment to drain out. Tighten drain cock.
CLEAN AIR CLEANER
1.
Locate the air filter assembly (Figure 51).
Remove access cover and remove outer
element of air filter assembly.
NOTE:
If indicator light on instrument
panel comes "ON," this
indicates that air cleaner needs
to be serviced.
NOTE:
Replace outer element every
1500 hours of service.
WARNING!
Be certain that hydraulic oil has cooled before draining water and sediment. Hot oil could splash
and cause burns.
The hydraulic tank is pressurized. Press button in center of breather to allow pressurized air to
vent. After pressure has been released, it is safe to remove either the fill cap or service covers.
CAUTION!
Never remove air cleaner element while
engine is running. This will allow dirt to be
sucked into engine and cause serious
engine damage. Always turn engine "OFF"
before servicing air cleaner.
Figure 49
AQO0170L
Figure 50