background image

 9150-065-Y-12-20

32

ON

EXI
LOO

FULL OPEN

DOORKING
4602-018

NC

NO

1

2

3

4

5

6

7

8

9

10

1

ENABLE STOP
SHORT PINS 1&2

2
3

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

FIRE

W

ARNING

MO

VI

NG 

GA

TE 

CAN 

CA

USE

Ope

rate

 ga

te onl

y wh

en 

gate

 are

a is

 in s

ight

and 

free

 of pe

opl

e a

nd ob

struc

tions

.

Do 

not 

allow

 chi

ldre

n to

 play

 in 

gat

e a

rea

or

 ope

rate

 ga

te.

Do 

not 

sta

nd i

n gate

 pa

th or

 wa

lk th

rough

pa

th

 w

hile

 ga

te is

 m

ovin

g.

Rea

d owne

r’s ma

nua

l an

d s

afe

ty ins

tru

ctio

ns

.

SER

IO

US

 IN

JU

RY

 OR

 DEA

TH

CLASS

CER

TIF

IED

 TO

CA

N/C

SA

 C2

2.

2 N

O. 2

47

CO

NF

OR

MS

 TO

AN

SI

/U

L-3

25

VEHI

CUL

AR

 GA

TE O

PE

RA

TOR

HP

533

82

MO

DE

L

SE

RIAL

VO

LTS

PH

ASE

AMPS

60

 Hz

MA

GA

TE

 LO

AD

Door

Ki

ng

, Inc

., Ing

lew

ood,

 CA

ON

ON

REVERS

E

SEN

SITIVIT

Y

REV

ER

SE

LOOP

EX

IT

LOOP

KE

Y SWITC

H

DOOR

KIN

G

4602

-0

10

SW

1

SW

2

OP

EN

TIM

ER

NC

1
2
3
4
5

NO

5.2 Control Wiring for Single/Primary Operator

Key Switch

Stand-Alone
Keypad

Stand-Alone
Card Reader

Telephone
Entry

Note:
All stand-alone and 
telephone entry 
devices must use a 
separate power 
source. 

Gate will 

ONLY OPEN

 when this device is activated by 

authorized personnel ONLY (fire, police, EMS) and operator 
has power. Alarm will sound during entire open cycle. 
Operator will then go into a hard shutdown once fully 
opened. Operator 

MUST

 be reset to function normally again. This device 

MUST

 be mounted 

in the line-of-site of gate so authorized personnel can monitor gate movement.

Dual Gate Operators Note: 

Connect device to 

BOTH

 operators, both gates will fully open.

Com

Com

Relay - 

#2 - Full Open.

 

#5 - Opens 14-feet.

Relay N.O. -  #2 - Full Open.
 

#5 - Opens gate 14-feet.

250 mA

max.

3-Wire Radio Receiver

ON

12

3

45678

SW 2

SW 2, 
switch 3 
must be

OFF

.

Relay Com

24 Volt Com

24 Volt - 250 mA max.

4-Wire
Receiver

#5 Terminal Note (Single Operator Only):

 

Any opening device connected to terminal 

#5 will open the gate to the partial open 14-ft 
setting. External entrapment protection devices 
will also open the gate to the partial open setting. 
If the 

Inherent Reverse Sensor

 gets activated 

during the close cycle, it will always 

fully

 open 

the gate.

24 volt

Full Open

Full Open

Stop

Com

Power

Com

Open

Close

Partial Open

3-Button Control
Station Jumper

Important:

 Controls intended for user activation must be located at least six (6) feet away from any moving part of the gate and where the user is prevented from 

reaching over, under, around or through the gate to operate the controls. Emergency access controls only accessible by authorized personnel (e.g., fire, police, 

EMS) may be placed at any location in the 
line-of-sight of the gate.

3

4

5

2

UL 325

Terminal

Pages 25-29

Open

Jumper Pins 1 & 2 

ONLY

 when

using a 4-wire control station
to 

enable

 stop terminal #7.

3-Button Control
Station Jumper

Factory Setting

Stop

Close

Com

4-Wire

3-Button

Control Station

(NC-Stop Circuit)

#4-Connected device fully opens gate.
#5-Connected device opens gate 14-feet.

Terminal #3 Note:

Exceeding 250 mA of power from 
this terminal may cause the circuit 
board transformer to overheat, 
causing intermittent problems.

OPE

N

STOP

CLOSE

1

2
3

1

2
3

IMPORTANT:

Leave 3-button control station 
jumper pins on 2 & 3 when 

NOT

 wiring a 

4-wire

 3-button 

control station to control 
board otherwise operator will 

NOT

 fuction.

Type of wiring to be used on ALL
external devices:
A)

 Type 

CL2

CL2P

CL2R

, or 

CL2X

B)

 Other cable with 

equivalent

 or

better

 electrical, mechanical, and

flammability ratings.

Activation Note:

 Activation of this device will 

OPEN 

gate regardless of the status of the open direction 

monitored external entrapment protection device(s). If gate is opening, and the operator’s 

inherent

 

entrapment protection system detects an obstruction, the operator will reverse approx. 2 inches and go into 
a hard shutdown. Operator reset button 

MUST

 be pushed to function again 

OR

 cycle operator’s power.

2-Pin

Supplied

Wire

Harness

Fire Dept

Open

Polypropylene Cover Note:

 

Allows wireless signal 
through cover.

Содержание 9150 Series

Страница 1: ...wh ile gat e is mo vin g Re ad ow ner s ma nua l and saf ety ins tru ctio ns SE RI OU S IN JU RY OR DE AT H CL AS S CE RT IFI ED TO CA N C SA C2 2 2 NO 24 7 CO NF OR MS TO AN SI UL 32 5 VE HI CU LA R...

Страница 2: ...sition Normal Setting Gate fully closes Gate stops short 1 from full close position Used for a reversing edge device Gate stops short 2 from full close position Used for a reversing edge device Gate s...

Страница 3: ...N input will re set and hold timer When gate is open auto close timer SW 1 switch 2 is turned OFF input will prevent gate from closing When gate is closing input will stop gate when SW 2 switch 2 is O...

Страница 4: ...e right to make changes in the products described in this manual without notice and without obligation of DoorKing Inc to notify any persons of any such revisions or changes Additionally DoorKing Inc...

Страница 5: ...OF GATE OPERATOR 45 8 1 Alarm Sounding OR Chirping and Gate WILL NOT Operate 8 2 Manual Gate Operation 8 3 Gate Operators Monthly Checkup 8 4 New Installation Checklist for Installer and Property Owne...

Страница 6: ...e to 2 1 4 inches or less Install a contact sensor in this area for safety See on next page and page 26 A gap measured in the horizontal plane parallel to the roadway between a fixed stationary object...

Страница 7: ...ns Non Contact Sensors Photo Sensors 1 2 Entrapment protection devices are required to reduce the risk of injury Install sensors where the risk of entrapment or obstruction exists while gate is moving...

Страница 8: ...reduce reversing sensitivity to compensate for a damaged gate For gate operators utilizing Type D protection 1 The gate operator controls must be placed so that the user has full view of the gate area...

Страница 9: ...s are installed a minimum distance of 6 feet away from the gate and gate operator or in such a way that a person cannot touch the gate or gate operator while using the device If access control devices...

Страница 10: ...Inherent entrapment protection system Type B1 Non contact sensor photoelectric sensor or the equivalent Type B2 Contact sensor edge device or equivalent Type C Inherent force limiting inherent adjust...

Страница 11: ...for vehicular traffic flow at entrances or exits to areas such as parking garages lots or toll areas VEHICULAR HORIZONTAL SLIDE GATE OPERATOR OR SYSTEM A vehicular gate operator or system that control...

Страница 12: ...ops Gate End Retainer Helps stabilize the end of the gate in the open or closed position Recommended for all slide gate applications Endless Idler Assembly with Protective Cover Helps to minimize a pi...

Страница 13: ...CSA C22 2 NO 247 CONFORMS TO ANSI UL 325 VEHICULAR GATE OPERATOR HP 53382 MODEL SERIAL VOLTS PHASE AMPS 60 Hz MAX GATE LOAD DoorKing Inc Inglewood CA WARN ING MOVING GATE CAN CAUSE Operate gate only w...

Страница 14: ...l stop for the gate Both are shown only one type is needed Base Plate Stop Bracket Chain Setup Chain Setup The Model 9150 operator is designed to be installed in the front rear center or ceiling mount...

Страница 15: ...oorKing Rear Position with Concrete Pad Hides the chain from outside the property looking in Chain setup is the same as above Rear Position with Post Mount Hides the chain from outside the property lo...

Страница 16: ...roperty looking in Optional chain tray kit can be used and is recommended for gates over 20 ft supports the chain s weight and helps prevent chain stretching See page 17 for more information Note Chai...

Страница 17: ...r and Communication wires Loop Lead In Wires Low Voltage wire insulation AC Input Power High Voltage wire insulation AC Input Power High Voltage wire insulation 3 4 Inch Conduit Recommended The condui...

Страница 18: ...e Weld the posts to the base plate and mount assembly into concrete BEFORE attaching the operator Conduit runs up through 6 x 6 steel posts Note Operator must be mounted 1 min away from gate Low Volt...

Страница 19: ...et Lines up with Idler Wheels Correct Chain Bracket Height Correct Chain Bracket Height Chain brackets positioned too low NO NO NO NO Chain Idler Wheels 1 minimum from operator housing to gate YES YES...

Страница 20: ...wheel wear and chain stretching Lower chain MUST align with upper chain Upper and lower chain MUST be the same height as they are on the operator idler wheels NO NO NO Gate Rail Gate Rail Chain Bracke...

Страница 21: ...he chain DoorKing offers a chain tray kit in sections to fit any length gate DoorKing P N 2601 270 10 Ft section Chain Tray Supporting Bracket Facing down Chain Tray Supporting Bracket Facing up Weep...

Страница 22: ...han the maximum distance shown it is recommended that a service feeder be installed When large gauge wire is used a separate junction box must be installed for the operator connection The wire table i...

Страница 23: ...e with local codes Be sure to color code all wiring It is recommended that a surge suppressor be installed on the high voltage power lines to help protect the operator and circuit board from surges an...

Страница 24: ...Detector Single Channel Loop Detector Dry Relay Contact N C N O Set the DIP switches on the circuit board to the desired setting See switch setting charts on next 2 pages DIP Switches ON 1 2 3 4 5 6 7...

Страница 25: ...g on a green light when the gate is full open If a magnetic lock is used with the gate operator these switches must be set for magnetic lock operation which limits the relay to activate only when the...

Страница 26: ...orized entry If switch 2 is turned OFF Reverse the closing gate that gets activated by a tailgating vehicle will reverse back to the open position possibly allowing the tailgating vehicle unauthorized...

Страница 27: ...powered up the first open command will automatically run Multiple gate cycles that will locate and remember the gate s open and close positions These positions are determined by the physical stops th...

Страница 28: ...est the operator reversing sensitivity Press the Key Switch button to cycle the gate While gate is cycling slowly rotate reverse sensor clockwise until the gate reverses direction Rotate reverse senso...

Страница 29: ...ov ing Read own er s man ual and safet y instr uctio ns SER IOU S INJ UR Y OR DE ATH CLA SS CER TIFI ED TO CAN CSA C22 2 NO 247 CON FOR MS TO ANS I UL 325 VEH ICU LAR GAT E OPE RAT OR HP 53382 MOD EL...

Страница 30: ...am 3 OPEN Edge 4 CLOSE Edge Only 1 monitored Device can be connected to each input An OPTIONAL Expansion Kit sold separately will allow connection for additional devices 1 OPEN Beam Switch 1 2 Ground...

Страница 31: ...ged into the built in convenience outlets located on the operator See page 25 See pages 2 and 26 for gate gap area and filler post information Open Beam Receiver MUST monitor for the presence of the t...

Страница 32: ...PE LEARN INPUT OUTPUT ASSIGNMENTS ON 1 2 3 4 5 6 A B X X 3 4 5 6 Model MIM 62 Class 2 Device Set to R Set 3 to A Output Set 4 to OFF See manufacturer s manual to LEARN open edges See manufacturer s ma...

Страница 33: ...E Beam 3 OPEN Edge 4 CLOSE Edge DIP switches MUST be turned ON for each device wired to terminal Wire Mesh CLOSE Beam photocell CLOSE Beam photocell A wide gate will not be protected from obstructions...

Страница 34: ...ns the gate for exiting vehicles without having to use a transmitter or keypad The exit loop can be placed a minimum of 4 feet away from the reverse loop or far enough away from the gate so the gate h...

Страница 35: ...ON input will re set and hold timer When gate is open auto close timer SW 1 switch 2 is turned OFF input will prevent gate from closing When gate is closing input will stop gate when SW 2 switch 2 is...

Страница 36: ...to the partial open 14 ft setting External entrapment protection devices will also open the gate to the partial open setting If the Inherent Reverse Sensor gets activated during the close cycle it wil...

Страница 37: ...nputs loop detector problems any forced entry attempts if the gate has struck anything during the open or close cycle power interruptions etc For more detailed information refer to the Tracker Install...

Страница 38: ...wired in parallel between primary and secondary operators SW 2 switch 1 must be OFF Plug into Primary Operator Exit Loop Port Dual Channel 9409 Automatic Exit Loop Reverse Loop Reverse Loop LL OPE LL...

Страница 39: ...with a rigid object or stop or reverse when an object activates the non contact sensors After adjusting the force or the limit of travel retest the gate operator Failure to adjust and retest the gate...

Страница 40: ...gate will reverse and run back to the closed position The time clock input is still present but the gate will not re open Example 2 If the gate is closing and an entrapment protection device is activa...

Страница 41: ...D that power to the operator has been SHUT OFF Solenoid Lock Clutch Plate SW 2 switch 4 must be OFF ON 1 2 3 4 5 6 7 8 SW 2 Note DoorKing operators have a built in alarm reset push button mounted on t...

Страница 42: ...bs truc tion s Do not allow child ren to play in gate area or ope rate gate Do not stan d in gate path or walk thro ugh path whil e gate is mov ing Rea d own er s man ual and safe ty inst ruct ions SE...

Страница 43: ...hen an obstruction is encountered Check for alignment tightness and wear Check vehicular exit and reverse loops for proper operation Check manual release for proper operation See page 46 Pulleys Check...

Страница 44: ...gh voltage supply A voltage drop on the supply line usually caused by using too small supply voltage wires will cause the operator to malfunction Refer to the wire size chart in section 2 1 on page 18...

Страница 45: ...om excess wires can diminish magnetic field Check that the magnetic pickup transistors on control board are within 1 8 inch of the clear plastic protective cover above the black plastic magnetic sprin...

Страница 46: ...ntains all the necessary wires to interconnect primary secondary operators Cable length 30 ft P N 2600 755 40 ft P N 2600 756 50 ft P N 2600 757 Time Clock 7 day time clock can be used to automaticall...

Страница 47: ...6 5 4 3 2 1 Brown White White Green Black Black White White Black White White Loop Yellow Red Red Yellow White Chassis Ground Board Ground Convenience Outlets Power Neutral Model 9150 1 2 HP 115 VAC...

Страница 48: ...ellow White Reset Button AC Power Switch MOV Assembly Brown White White Green Black Black White White Black Red Yellow White Chassis Ground Board Ground Convenience Outlets Motor Resistors Power Neutr...

Страница 49: ...mpletes the reverse cycle the inherent entrapment protection system Type A gets activated If a Fire Dept Access Device has been activated by emergency personnel then operator can be reset and put back...

Страница 50: ...ONS for more information about operating this gate operator Gate CANNOT be manually PUSHED open until FAIL SECURE Lock has been UNLOCKED WARNIN G MOV IN G GA TE CA N CA US E Ope rate gat e onl y whe n...

Страница 51: ...the gate will resume opening when the beam is clear If gate does NOT respond like it should in either direction of gate travel contact a trained service technician to make adjustments or repairs Test...

Страница 52: ...installer AND property owner If it is not applicable enter N A Please note that the checklist is intended to be a summary of many important automated vehicular gate aspects But may not inclusively id...

Страница 53: ...STRUCTIONS for more information about operating this gate operator When Alarm is Sounding OR Chirping Operator is in a HARD Shutdown Condition The alarm will sound for 5 five minutes After five minute...

Страница 54: ...25 August 2018 Standard Entrapment Protection must be provided for the gate system where the risk of entrapment or obstruction exists The operator will NOT run without one or more monitored type B1 or...

Отзывы: